The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Plasmon-Enhanced Colorimetric ELISA with Single Molecule Sensitivity
Abstract
Robust but ultrasensitive biosensors with a capability of detecting low abundance biomarkers could revolutionize clinical diagnostics and enable early detection of cancer, neurological diseases, and infections. We utilized a combination of localized surface plasmon resonance (LSPR) refractive index sensing and the well-known enzyme-linked immunosorbent assay to develop a simple colorimetric biosensing methodology with single molecule sensitivity. The technique is based on spectral imaging of a large number of isolated gold nanoparticles. Each particle binds a variable number of horseradish peroxidase (HRP) enzyme molecules that catalyze a localized precipitation reaction at the particle surface. The enzymatic reaction dramatically amplifies the shift of the LSPR scattering maximum, λ(max), and makes it possible to detect the presence of only one or a few HRP molecules per particle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weighing of biomolecules, single cells and single nanoparticles in fluid
Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R. (2007) · Nature · doi:10.1038/nature05741 · Cited by 1,213
Cited by
Plasmonic ELISA for the ultrasensitive detection of disease biomarkers with the naked eye
de la Rica, R., & Stevens, M. M. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.186 · Cited by 873
Zijlstra, P., Paulo, P. M. R., & Orrit, M. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.51 · Cited by 788
LSPR Chip for Parallel, Rapid, and Sensitive Detection of Cancer Markers in Serum
Aćimović, S. S., Ortega, M. A., Sanz, V., Berthelot, J., Garcia-Cordero, J. L., Renger, J., Maerkl, S. J., Kreuzer, M. P., & Quidant, R. (2014) · Nano Letters · doi:10.1021/nl500574n · Cited by 310
Metadata
- Authors
- Chen, S., Svedendahl, M., Van Duyne, R. P., & Käll, M.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-03-23
- Volume
- 11
- Issue
- 4
- Pages
- 1826-1830
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W1997946708
- Cited by
- 186
- References
- 1
- FWCI
- 8.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.