Flexible Fiber Nanogenerator with 209 V Output Voltage Directly Powers a Light-Emitting Diode
Abstract
On the basis of a vertically aligned ultralong Pb(Zr(0.52)Ti(0.48))O(3) (PZT) nanowire array fabricated using electrospinning nanofibers, we developed a new type of integrated nanogenerator (NG) with ultrahigh output voltage of 209 V and current density of 23.5 μA/cm(2), which are 3.6 times and 2.9 times of the previous record values, respectively. The output electricity can be directly used to stimulate the frog's sciatic nerve and to induce a contraction of a frog's gastrocnemius. The NG can instantaneously power a commercial light-emitting diode (LED) without the energy storage process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Self-citationXu, S., Qin, Y., Xu, C., Wei, Y., Yang, R., & Wang, Z. L. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.46 · Cited by 1,626
Self-citationMicrofibre–nanowire hybrid structure for energy scavenging
Qin, Y., Wang, X., & Wang, Z. L. (2008) · Nature · doi:10.1038/nature06601 · Cited by 1,610
Self-citation1.6 V Nanogenerator for Mechanical Energy Harvesting Using PZT Nanofibers
Chen, X., Xu, S., Yao, N., & Shi, Y. (2010) · Nano Letters · doi:10.1021/nl100812k · Cited by 900
Piezoelectric BaTiO3Thin Film Nanogenerator on Plastic Substrates
Park, K.-I., Xu, S., Liu, Y., Hwang, G.-T., Kang, S.-J. L., Wang, Z. L., & Lee, K. J. (2010) · Nano Letters · doi:10.1021/nl102959k · Cited by 827
Self-citationFlexible High-Output Nanogenerator Based on Lateral ZnO Nanowire Array
Zhu, G., Yang, R., Wang, S., & Wang, Z. L. (2010) · Nano Letters · doi:10.1021/nl101973h · Cited by 805
Self-citationPiezoelectric-nanowire-enabled power source for driving wireless microelectronics
Xu, S., Hansen, B. J., & Wang, Z. L. (2010) · Nature Communications · doi:10.1038/ncomms1098 · Cited by 546
Self-citationWu, W., Bai, S., Yuan, M., Qin, Y., Wang, Z. L., & Jing, T. (2012) · ACS Nano · doi:10.1021/nn3016585 · Cited by 389
Self-citationPorous PVDF As Effective Sonic Wave Driven Nanogenerators
Cha, S., Kim, S. M., Kim, H., Ku, J., Sohn, J. I., Park, Y. J., Song, B. G., Jung, M. H., Lee, E. K., Choi, B. L., et al. (2011) · Nano Letters · doi:10.1021/nl202208n · Cited by 382
Self-citationMembrane currents in isolated frog nerve fibre under voltage clamp conditions
Dodge, F. A., & FRANKENHAEUSER, B. (1958) · The Journal of Physiology · doi:10.1113/jphysiol.1958.sp006045 · Cited by 352
Functional Electrical Stimulation by Nanogenerator with 58 V Output Voltage
Zhu, G., Wang, A. C., Liu, Y., Zhou, Y., & Wang, Z. L. (2012) · Nano Letters · doi:10.1021/nl300972f · Cited by 335
Self-citationPiezoelectric nanogenerator using CdS nanowires
Lin, Y.-F., Song, J., Ding, Y., Lu, S.-Y., & Wang, Z. L. (2008) · Applied Physics Letters · doi:10.1063/1.2831901 · Cited by 318
Self-citationHu, Y., Xu, C., Zhang, Y., Lin, L., Snyder, R. L., & Wang, Z. L. (2011) · Advanced Materials · doi:10.1002/adma.201102067 · Cited by 275
Self-citationHu, Y., Zhang, Y., Xu, C., Zhu, G., & Wang, Z. L. (2010) · Nano Letters · doi:10.1021/nl103203u · Cited by 261
Self-citationSelf-powered environmental sensor system driven by nanogenerators
Lee, M., Bae, J., Lee, J., Lee, C.-S., Hong, S., & Wang, Z. L. (2011) · Energy & Environmental Science · doi:10.1039/c1ee01558c · Cited by 230
Self-citationP-Type Polymer-Hybridized High-Performance Piezoelectric Nanogenerators
Lee, K. Y., Kumar, B., Seo, J.-S., Kim, K.-H., Sohn, J. I., Cha, S. N., Choi, D., Wang, Z. L., & Kim, S.-W. (2012) · Nano Letters · doi:10.1021/nl204440g · Cited by 218
Self-citationEffects of nerve impulses on threshold of frog sciatic nerve fibres.
Raymond, S. A. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012771 · Cited by 134
FRANKENHAEUSER, B. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005729 · Cited by 98
High output nanogenerator based on assembly of GaN nanowires
Lin, L., Lai, C.-H., Hu, Y., Zhang, Y., Wang, X., Xu, C. G., Snyder, R. L., Chen, L.-J., & Wang, Z. L. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/47/475401 · Cited by 88
Self-citation
Cited by
Flexible Nanogenerators for Energy Harvesting and Self‐Powered Electronics
Fan, F. R., Tang, W., & Wang, Z. L. (2016) · Advanced Materials · doi:10.1002/adma.201504299 · Cited by 1,918
Self-citationPark, J., Kim, M., Lee, Y., Lee, H. S., & Ko, H. (2015) · Science Advances · doi:10.1126/sciadv.1500661 · Cited by 939
Hwang, G., Park, H., Lee, J., Oh, S., Park, K., Byun, M., Park, H., Ahn, G., Jeong, C. K., No, K., et al. (2014) · Advanced Materials · doi:10.1002/adma.201400562 · Cited by 672
Recent Progress on Piezoelectric and Triboelectric Energy Harvesters in Biomedical Systems
Zheng, Q., Shi, B., Li, Z., & Wang, Z. L. (2017) · Advanced Science · doi:10.1002/advs.201700029 · Cited by 566
Self-citationThakur, P., Kool, A., Hoque, N. A., Bagchi, B., Khatun, F., Biswas, P., Brahma, D., Roy, S., Banerjee, S., & Das, S. (2018) · Nano Energy · doi:10.1016/j.nanoen.2017.11.065 · Cited by 313
Metadata
- Authors
- Gu, L., Cui, N., Cheng, L., Xu, Q., Bai, S., Yuan, M., Wu, W., Liu, J., Zhao, Y., Ma, F., Qin, Y., & Wang, Z. L.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-12-11
- Volume
- 13
- Issue
- 1
- Pages
- 91-94
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W1991098189
- Cited by
- 307
- References
- 19
- FWCI
- 10.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.