Wide-Field Multispectral Super-Resolution Imaging Using Spin-Dependent Fluorescence in Nanodiamonds
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Recent advances in fluorescence microscopy have enabled spatial resolution below the diffraction limit by localizing multiple temporally or spectrally distinguishable fluorophores. Here, we introduce a super-resolution technique that deterministically controls the brightness of uniquely addressable, photostable emitters. We modulate the fluorescence brightness of negatively charged nitrogen-vacancy (NV(-)) centers in nanodiamonds through magnetic resonance techniques. Using a CCD camera, this "deterministic emitter switch microscopy" (DESM) technique enables super-resolution imaging with localization down to 12 nm across a 35 × 35 μm(2) area. DESM is particularly well suited for biological applications such as multispectral particle tracking since fluorescent nanodiamonds are not only cytocompatible but also nonbleaching and bright. We observe fluorescence count rates exceeding 1.5 × 10(6) photons per second from single NV(-) centers at saturation. When combined with emerging NV(-)-based techniques for sensing magnetic and electric fields, DESM opens the door to rapid, super-resolution imaging for tracking and sensing applications in the life and physical sciences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Shim, S.-H., Xia, C., Zhong, G., Babcock, H. P., Vaughan, J. C., Huang, B., Wang, X., Xu, C., Bi, G.-Q., & Zhuang, X. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201882109 · Cited by 514
Cited by
Hsiao, W. W.-W., Hui, Y. Y., Tsai, P.-C., & Chang, H.-C. (2016) · Accounts of Chemical Research · doi:10.1021/acs.accounts.5b00484 · Cited by 365
Aharonovich, I., & Neu, E. (2014) · Advanced Optical Materials · doi:10.1002/adom.201400189 · Cited by 359
Biomedical applications of nanodiamond (Review)
Turcheniuk, K., & Mochalin, V. N. (2017) · Nanotechnology · doi:10.1088/1361-6528/aa6ae4 · Cited by 324
Nanoparticles for super-resolution microscopy and single-molecule tracking
Jin, D., Xi, P., Wang, B., Zhang, L., Enderlein, J., & van Oijen, A. M. (2018) · Nature Methods · doi:10.1038/s41592-018-0012-4 · Cited by 283
Simultaneous Broadband Vector Magnetometry Using Solid-State Spins
Schloss, J. M., Barry, J. F., Turner, M. J., & Walsworth, R. L. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.10.034044 · Cited by 270
Metadata
- Authors
- Chen, E. H., Gaathon, O., Trusheim, M. E., & Englund, D.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-04-08
- Volume
- 13
- Issue
- 5
- Pages
- 2073-2077
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2319655619
- Cited by
- 91
- References
- 2
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.