Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 319

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Significantly Improved Long-Cycle Stability in High-Rate Li–S Batteries Enabled by Coaxial Graphene Wrapping over Sulfur-Coated Carbon Nanofibers

Lu, Songtao, Cheng, Yingwen, Wu, Xiaohong, Liu, Jie·2013·Nano Letters

Abstract

Long-term instability of Li-S batteries is one of their major disadvantages compare to other secondary batteries. The reasons for the instability include dissolution of polysulfide intermediates and mechanical instability of the electrode film caused by volume changes during charging/discharging cycles. In this paper, we report a novel graphene-sulfur-carbon nanofibers (G-S-CNFs) multilayer and coaxial nanocomposite for the cathode of Li-S batteries with increased capacity and significantly improved long-cycle stability. Electrodes made with such nanocomposites were able to deliver a reversible capacity of 694 mA h g(-1) at 0.1C and 313 mA h g(-1) at 2C, which are both substantially higher than electrodes assembled without graphene wrapping. More importantly, the long-cycle stability was significantly improved by graphene wrapping. The cathode made with G-S-CNFs with a initial capacity of 745 mA h g(-1) was able to maintain ~273 mA h g(-1) even after 1500 charge-discharge cycles at a high rate of 1C, representing an extremely low decay rate (0.043% per cycle after 1500 cycles). In contrast, the capacity of an electrode assembled without graphene wrapping decayed dramatically with a 10 times high rate (~0.40% per cycle after 200 cycles). These results demonstrate that the coaxial nanocomposites are of great potential as the cathode for high-rate rechargeable Li-S batteries. Such improved rate capability and cycle stability could be attributed to the unique coaxial architecture of the nanocomposite, in which the contributions from graphene and CNFs enable electrodes with improved electrical conductivity, better ability to trap soluble the polysulfides intermediate and accommodate volume expansion/shrinkage of sulfur during repeated charge/discharge cycles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/nl400543y

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

Metadata

Authors
Lu, S., Cheng, Y., Wu, X., & Liu, J.
Venue
Nano Letters
Published
2013-05-22
Volume
13
Issue
6
Pages
2485-2489
ISSN
  • 1530-6984 (ISSN-L)
  • 1530-6992
OpenAlex
W2328166017
Cited by
319
References
34
FWCI
31.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Significantly Improved Long-Cycle Stability in High-Rate Li–S Batteries Enabled by Coaxial Graphene Wrapping over Sulfur-Coated Carbon Nanofibers. https://app.cochat.ai/papers/10.1021/nl400543y
The paper
Lu, S., Cheng, Y., Wu, X., & Liu, J. (2013). Significantly Improved Long-Cycle Stability in High-Rate Li–S Batteries Enabled by Coaxial Graphene Wrapping over Sulfur-Coated Carbon Nanofibers. Nano Letters. https://doi.org/10.1021/nl400543y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.