The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Photoelectrochemical Detection of Glutathione by IrO2–Hemin–TiO2 Nanowire Arrays
Abstract
We have developed sensitive detection of glutathione using the IrO2-hemin-TiO2 nanowire arrays. Single-crystalline TiO2 nanowires are synthesized by a hydrothermal reaction, followed by surface functionalization of ~3 nm thick hemin and ~1-2 nm diameter IrO2 nanoparticles. The IrO2-hemin-TiO2 nanowire arrays offer much enhanced photocurrent with ∼100% increase compared to the pristine TiO2 nanowires and allow for label-free, real-time, sensitive photoelectrochemical detection of glutathione. The sensitivity achieved is ~10 nM in buffer, comparable to or better than most of the existing glutathione detection methods. Furthermore, cell extracts containing glutathione are robustly detected, with ~8000 cells/mL for HeLa cells and ~5000 cells/mL for human embryonic kidney 293T cells. This nanowire PEC sensor assay exhibits excellent selectivity and stability, suggesting a potential detection platform for analyzing the glutathione level in biosamples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Graphene‐Supported Hemin as a Highly Active Biomimetic Oxidation Catalyst
Xue, T., Jiang, S., Qu, Y., Su, Q., Cheng, R., Dubin, S., Chiu, C., Kaner, R., Huang, Y., & Duan, X. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201108400 · Cited by 365
Cited by
Photoelectrochemical bioanalysis: the state of the art
Zhao, W.-W., Xu, J.-J., & Chen, H.-Y. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00228h · Cited by 912
Photoelectrochemical DNA Biosensors
Zhao, W.-W., Xu, J.-J., & Chen, H.-Y. (2014) · Chemical Reviews · doi:10.1021/cr500100j · Cited by 857
Tian, J., Zhao, Z., Kumar, A., Boughton, R. I., & Liu, H. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00180j · Cited by 804
A review on molten salt synthesis of metal oxide nanomaterials: Status, opportunity, and challenge
Gupta, S. K., & Mao, Y. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100734 · Cited by 362
Devadoss, A., Sudhagar, P., Terashima, C., Nakata, K., & Fujishima, A. (2015) · Journal of Photochemistry and Photobiology C: Photochemistry Reviews · doi:10.1016/j.jphotochemrev.2015.06.002 · Cited by 298
Metadata
- Authors
- Tang, J., Kong, B., Wang, Y., Xu, M., Wang, Y., Wu, H., & Zheng, G.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-10-01
- Volume
- 13
- Issue
- 11
- Pages
- 5350-5354
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2316693411
- Cited by
- 225
- References
- 1
- FWCI
- 15.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photoelectrochemical Detection of Glutathione by IrO2–Hemin–TiO2 Nanowire Arrays. https://app.cochat.ai/papers/10.1021/nl4028507
- The paper
- Tang, J., Kong, B., Wang, Y., Xu, M., Wang, Y., Wu, H., & Zheng, G. (2013). Photoelectrochemical Detection of Glutathione by IrO2–Hemin–TiO2 Nanowire Arrays. Nano Letters. https://doi.org/10.1021/nl4028507
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.