The DOI matches its Crossref record.
Toward Plasmonics with Nanometer Precision: Nonlinear Optics of Helium-Ion Milled Gold Nanoantennas
Abstract
Plasmonic nanoantennas are versatile tools for coherently controlling and directing light on the nanoscale. For these antennas, current fabrication techniques such as electron beam lithography (EBL) or focused ion beam (FIB) milling with Ga(+)-ions routinely achieve feature sizes in the 10 nm range. However, they suffer increasingly from inherent limitations when a precision of single nanometers down to atomic length scales is required, where exciting quantum mechanical effects are expected to affect the nanoantenna optics. Here, we demonstrate that a combined approach of Ga(+)-FIB and milling-based He(+)-ion lithography (HIL) for the fabrication of nanoantennas offers to readily overcome some of these limitations. Gold bowtie antennas with 6 nm gap size were fabricated with single-nanometer accuracy and high reproducibility. Using third harmonic (TH) spectroscopy, we find a substantial enhancement of the nonlinear emission intensity of single HIL-antennas compared to those produced by state-of-the-art gallium-based milling. Moreover, HIL-antennas show a vastly improved polarization contrast. This superior nonlinear performance of HIL-derived plasmonic structures is an excellent testimonial to the application of He(+)-ion beam milling for ultrahigh precision nanofabrication, which in turn can be viewed as a stepping stone to mastering quantum optical investigations in the near-field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Probing the mechanisms of large Purcell enhancement in plasmonic nanoantennas
Akselrod, G. M., Argyropoulos, C., Hoang, T. B., Ciracì, C., Fang, C., Huang, J., Smith, D. R., & Mikkelsen, M. H. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.228 · Cited by 1,084
Gold Nanorods: The Most Versatile Plasmonic Nanoparticles
Zheng, J., Cheng, X., Zhang, H., Bai, X., Ai, R., Shao, L., & Wang, J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00422 · Cited by 651
Kang, H., Buchman, J. T., Rodriguez, R. S., Ring, H. L., He, J., Bantz, K. C., & Haynes, C. L. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00341 · Cited by 635
Li, P., Chen, S., Dai, H., Yang, Z., Chen, Z., Wang, Y., Chen, Y., Peng, W., Shan, W., & Duan, H. (2021) · Nanoscale · doi:10.1039/d0nr07539f · Cited by 314
Metasurface-assisted phase-matching-free second harmonic generation in lithium niobate waveguides
Wang, C., Li, Z., Kim, M.-H., Xiong, X., Ren, X.-F., Guo, G.-C., Yu, N., & Lončar, M. (2017) · Nature Communications · doi:10.1038/s41467-017-02189-6 · Cited by 208
Metadata
- Authors
- Kollmann, H., Piao, X., Esmann, M., Becker, S. F., Hou, D., Huynh, C., Kautschor, L.-O., Bösker, G., Vieker, H., Beyer, A., Gölzhäuser, A., Park, N., Vogelgesang, R., Silies, M., & Lienau, C.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-07-25
- Volume
- 14
- Issue
- 8
- Pages
- 4778-4784
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2022586821
- Cited by
- 198
- References
- 0
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.