Optimizing the Signal-to-Noise Ratio for Biosensing with Carbon Nanotube Transistors
The DOI matches its Crossref record.
Abstract
The signal-to-noise ratio (SNR) for real-time biosensing with liquid-gated carbon nanotube transistors is crucial for exploring the limits of their sensitivity, but has not been studied thus far. Although biosensing is often performed at high transconductance where the device displays the largest gate response, here we show that the maximum SNR is actually obtained when the device is operated in the subthreshold regime. In the ON-state, additional contributions to the noise can lead to a reduction of the SNR by up to a factor of 5. For devices with passivated contact regions, the SNR in ON-state is even further reduced than for bare devices. We show that when the conductivity of the contact regions can be increased using a conventional back gate, the SNR in the ON-state can be improved. The results presented here demonstrate that biosensing experiments are best performed in the subthreshold regime for optimal SNR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Carbon Nanomaterials in Biosensors: Should You Use Nanotubes or Graphene?
Yang, W., Ratinac, K. R., Ringer, S. P., Thordarson, P., Gooding, J. J., & Braet, F. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200903463 · Cited by 1,431
Subthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571
Carbon as catalyst and support for electrochemical energy conversion
Trogadas, P., Fuller, T. F., & Strasser, P. (2014) · Carbon · doi:10.1016/j.carbon.2014.04.005 · Cited by 522
Nernst Limit in Dual-Gated Si-Nanowire FET Sensors
Knopfmacher, O., Tarasov, A., Fu, W., Wipf, M., Niesen, B., Calame, M., & Schönenberger, C. (2010) · Nano Letters · doi:10.1021/nl100892y · Cited by 353
Effect of Nanowire Number, Diameter, and Doping Density on Nano-FET Biosensor Sensitivity
Li, J., Zhang, Y., To, S., You, L., & Sun, Y. (2011) · ACS Nano · doi:10.1021/nn202182p · Cited by 138
Optimization of the Sensitivity of FET-Based Biosensors via Biasing and Surface Charge Engineering
Shoorideh, K., & Chui, C. O. (2012) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2214221 · Cited by 65
Metadata
- Authors
- Heller, I., Männik, J., Lemay, S. G., & Dekker, C.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-01-14
- Volume
- 9
- Issue
- 1
- Pages
- 377-382
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2055539731
- Cited by
- 86
- References
- 0
- FWCI
- 8.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.