Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 213

The DOI matches its Crossref record.

Long-Range Fluorescence Quenching by Gold Nanoparticles in a Sandwich Immunoassay for Cardiac Troponin T

Mayilo, Sergiy, Kloster, Meike A., Wunderlich, Michael, Lutich, Andrey, Klar, Thomas A., Nichtl, Alfons, Kürzinger, Konrad, Stefani, Fernando D., Feldmann, Jochen·2009·Nano Letters

Abstract

We report the first homogeneous sandwich immunoassay with gold nanoparticles (AuNPs) as fluorescence quenchers. The sandwich assay is designed for the detection of the protein cardiac troponin T (cTnT) by its simultaneous interaction with two different antibodies, one attached to AuNPs and the other labeled with fluorescent dyes. We demonstrate the working principle of the assay and using time-resolved fluorescence spectroscopy, we determine the quenching efficiency of the gold nanoparticles. In spite of the relatively large separation distance between dye molecules and AuNPs, ranging from 3 to 22 nm, the AuNPs quench the fluorescence with efficiencies as high as 95%. A limit of detection of 0.02 nM (0.7 ng/mL) was obtained for cTnT, which is the lowest value reported for a homogeneous sandwich assay for cTnT. These results illustrate the use of metallic nanoparticles as fluorescence quenchers in immunoassays where the large biomolecules involved impose distances for which energy transfer between fluorophores would be inefficient.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/nl903178n

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Mayilo, S., Kloster, M. A., Wunderlich, M., Lutich, A., Klar, T. A., Nichtl, A., Kürzinger, K., Stefani, F. D., & Feldmann, J.
Venue
Nano Letters
Published
2009-11-18
Volume
9
Issue
12
Pages
4558-4563
ISSN
  • 1530-6984 (ISSN-L)
  • 1530-6992
OpenAlex
W1983586473
Cited by
213
References
0
FWCI
8.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.