The DOI matches its Crossref record.
Smaller is Faster and More Sensitive: The Effect of Wire Size on the Detection of Hydrogen by Single Palladium Nanowires
Abstract
Palladium nanowires prepared using the lithographically patterned nanowire electrodeposition (LPNE) method are used to detect hydrogen gas (H2). These palladium nanowires are prepared by electrodepositing palladium from EDTA-containing solutions under conditions favoring the formation of β-phase PdHx. The Pd nanowires produced by this procedure are characterized by X-ray diffraction, transmission electron microscopy, scanning electron microscopy, atomic force microscopy, and X-ray photoelectron spectroscopy. These nanowires have a mean grain diameter of 15 nm and are composed of pure Pd with no XPS-detectable bulk carbon. The four-point resistance of 50-100 μm segments of individual nanowires is used to detect H2 in N2 and air at concentrations ranging from 2 ppm to 10%. For low [H2] < 1%, the response amplitude increases by a factor of 2-3 with a reduction in the lateral dimensions of the nanowire. Smaller nanowires show accelerated response and recovery rates at all H2 concentrations from, 5 ppm to 10%. For 12 devices, response and recovery times are correlated with the surface area/volume ratio of the palladium detection element. We conclude that the kinetics of hydrogen adsorption limits the observed response rate seen for the nanowire, and that hydrogen desorption from the nanowire limits the observed recovery rate; proton diffusion within PdHx does not limit the rates of either of these processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanoantenna-enhanced gas sensing in a single tailored nanofocus
Liu, N., Tang, M. L., Hentschel, M., Giessen, H., & Alivisatos, A. P. (2011) · Nature Materials · doi:10.1038/nmat3029 · Cited by 950
The role of palladium in a hydrogen economy
Adams, B. D., & Chen, A. (2011) · Materials Today · doi:10.1016/s1369-7021(11)70143-2 · Cited by 565
Active metamaterials and metadevices: a review
Xiao, S., Wang, T., Liu, T., Zhou, C., Jiang, X., & Zhang, J. (2020) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/abaced · Cited by 429
Darmadi, I., Nugroho, F. A. A., & Langhammer, C. (2020) · ACS Sensors · doi:10.1021/acssensors.0c02019 · Cited by 382
Chemiresistive Hydrogen Sensors: Fundamentals, Recent Advances, and Challenges
Koo, W.-T., Cho, H.-J., Kim, D.-H., Kim, Y. H., Shin, H., Penner, R. M., & Kim, I.-D. (2020) · ACS Nano · doi:10.1021/acsnano.0c05307 · Cited by 379
Self-citationMetal–polymer hybrid nanomaterials for plasmonic ultrafast hydrogen detection
Nugroho, F. A. A., Darmadi, I., Cusinato, L., Susarrey-Arce, A., Schreuders, H., Bannenberg, L. J., da Silva Fanta, A. B., Kadkhodazadeh, S., Wagner, J. B., Antosiewicz, T. J., et al. (2019) · Nature Materials · doi:10.1038/s41563-019-0325-4 · Cited by 365
Synthesis of Stable Shape-Controlled Catalytically Active β-Palladium Hydride
Zhao, Z., Huang, X., Li, M., Wang, G., Lee, C., Zhu, E., Duan, X., & Huang, Y. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b11543 · Cited by 155
Enhancing H2 evolution by optimizing H adatom combination and desorption over Pd nanocatalyst
Wang, J., Tan, H., Jiang, D., & Zhou, K. (2017) · Nano Energy · doi:10.1016/j.nanoen.2017.02.001 · Cited by 54
Fazio, E., Leonardi, S. G., Santoro, M., Donato, N., Neri, G., & Neri, F. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.01.217 · Cited by 14
Metadata
- Authors
- Yang, F., Kung, S.-C., Cheng, M., Hemminger, J. C., & Penner, R. M.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-08-13
- Volume
- 4
- Issue
- 9
- Pages
- 5233-5244
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2017633284
- Cited by
- 241
- References
- 0
- FWCI
- 12.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.