The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
EGFR-Targeted Magnetic Nanoparticle Heaters Kill Cancer Cells without a Perceptible Temperature Rise
Abstract
It is currently believed that magnetic nanoparticle heaters (MNHs) can kill cancer cells only when the temperature is raised above 43 °C due to energy dissipation in an alternating magnetic field. On the other hand, simple heat conduction arguments indicate that in small tumors or single cells the relative rates of energy dissipation and heat conduction result in a negligible temperature rise, thus limiting the potential of MNHs in treating small tumors and metastatic cancer. Here we demonstrate that internalized MNHs conjugated to epidermal growth factor (EGF) and which target the epidermal growth factor receptor (EGFR) do result in a significant (up to 99.9%) reduction in cell viability and clonogenic survival in a thermal heat dose dependent manner, without the need for a perceptible temperature rise. The effect appears to be cell type specific and indicates that magnetic nanoparticles in alternating magnetic fields may effectively kill cancer cells under conditions previously considered as not possible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The effect of thermotherapy using magnetic nanoparticles on rat malignant glioma
Jordan, A., Scholz, R., Maier-Hauff, K., van Landeghem, F. K. H., Waldoefner, N., Teichgraeber, U., Pinkernelle, J., Bruhn, H., Neumann, F., Thiesen, B., et al. (2006) · Journal of Neuro-Oncology · doi:10.1007/s11060-005-9059-z · Cited by 459
Cited by
Fundamentals and advances in magnetic hyperthermia
Périgo, E. A., Hemery, G., Sandre, O., Ortega, D., Garaio, E., Plazaola, F., & Teran, F. J. (2015) · Applied Physics Reviews · doi:10.1063/1.4935688 · Cited by 836
Dutz, S., & Hergt, R. (2013) · International Journal of Hyperthermia · doi:10.3109/02656736.2013.822993 · Cited by 522
Tay, Z. W., Chandrasekharan, P., Chiu-Lam, A., Hensley, D. W., Dhavalikar, R., Zhou, X. Y., Yu, E. Y., Goodwill, P. W., Zheng, B., Rinaldi, C., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b00893 · Cited by 459
Nanoparticles for Imaging, Sensing, and Therapeutic Intervention
Bogart, L. K., Pourroy, G., Murphy, C. J., Puntes, V., Pellegrino, T., Rosenblum, D., Peer, D., & Lévy, R. (2014) · ACS Nano · doi:10.1021/nn500962q · Cited by 295
Design of iron oxide-based nanoparticles for MRI and magnetic hyperthermia
Blanco-Andujar, C., Walter, A., Cotin, G., Bordeianu, C., Mertz, D., Felder-Flesch, D., & Begin-Colin, S. (2016) · Nanomedicine · doi:10.2217/nnm-2016-5001 · Cited by 276
Metadata
- Authors
- Creixell, M., Bohórquez, A. C., Torres-Lugo, M., & Rinaldi, C.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-08-22
- Volume
- 5
- Issue
- 9
- Pages
- 7124-7129
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2315718304
- Cited by
- 325
- References
- 1
- FWCI
- 15.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EGFR-Targeted Magnetic Nanoparticle Heaters Kill Cancer Cells without a Perceptible Temperature Rise. https://app.cochat.ai/papers/10.1021/nn201822b
- The paper
- Creixell, M., Bohórquez, A. C., Torres-Lugo, M., & Rinaldi, C. (2011). EGFR-Targeted Magnetic Nanoparticle Heaters Kill Cancer Cells without a Perceptible Temperature Rise. ACS Nano. https://doi.org/10.1021/nn201822b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.