The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Template-Stripped Smooth Ag Nanohole Arrays with Silica Shells for Surface Plasmon Resonance Biosensing
Open accessAbstract
Inexpensive, reproducible, and high-throughput fabrication of nanometric apertures in metallic films can benefit many applications in plasmonics, sensing, spectroscopy, lithography, and imaging. Here we use template-stripping to pattern periodic nanohole arrays in optically thick, smooth Ag films with a silicon template made via nanoimprint lithography. Ag is a low-cost material with good optical properties, but it suffers from poor chemical stability and biocompatibility. However, a thin silica shell encapsulating our template-stripped Ag nanoholes facilitates biosensing applications by protecting the Ag from oxidation as well as providing a robust surface that can be readily modified with a variety of biomolecules using well-established silane chemistry. The thickness of the conformal silica shell can be precisely tuned by atomic layer deposition, and a 15 nm thick silica shell can effectively prevent fluorophore quenching. The Ag nanohole arrays with silica shells can also be bonded to polydimethylsiloxane (PDMS) microfluidic channels for fluorescence imaging, formation of supported lipid bilayers, and real-time, label-free SPR sensing. Additionally, the smooth surfaces of the template-stripped Ag films enhance refractive index sensitivity compared with as-deposited, rough Ag films. Because nearly centimeter-sized nanohole arrays can be produced inexpensively without using any additional lithography, etching, or lift-off, this method can facilitate widespread applications of metallic nanohole arrays for plasmonics and biosensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of the Noble Metals
Johnson, P. B., & Christy, R. W. (1972) · Physical Review B · doi:10.1103/physrevb.6.4370 · Cited by 20,094
Cited by
SPR Biosensors: Historical Perspectives and Current Challenges
Singh, P. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.01.118 · Cited by 608
Trends and challenges of refractometric nanoplasmonic biosensors: A review
Estevez, M.-C., Otte, M. A., Sepulveda, B., & Lechuga, L. M. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.10.048 · Cited by 301
Recent developments in biosensors for healthcare and biomedical applications: A review
Mohankumar, P., Ajayan, J., Mohanraj, T., & Yasodharan, R. (2021) · Measurement · doi:10.1016/j.measurement.2020.108293 · Cited by 266
Nanoplasmonic sensors for biointerfacial science
Jackman, J. A., Rahim Ferhan, A., & Cho, N.-J. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00494f · Cited by 258
Infrared Plasmonic Biosensor for Real-Time and Label-Free Monitoring of Lipid Membranes
Limaj, O., Etezadi, D., Wittenberg, N. J., Rodrigo, D., Yoo, D., Oh, S.-H., & Altug, H. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b05316 · Cited by 196
Self-citation
Metadata
- Authors
- Im, H., Lee, S. H., Wittenberg, N. J., Johnson, T. W., Lindquist, N. C., Nagpal, P., Norris, D. J., & Oh, S.-H.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-07-27
- Volume
- 5
- Issue
- 8
- Pages
- 6244-6253
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2074164867
- Cited by
- 229
- References
- 1
- FWCI
- 6.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.