The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Enzymatic Oxygen Scavenging for Photostability without pH Drop in Single-Molecule Experiments
Open accessAbstract
Over the past years, bottom-up bionanotechnology has been developed as a promising tool for future technological applications. Many of these biomolecule-based assemblies are characterized using various single-molecule techniques that require strict anaerobic conditions. The most common oxygen scavengers for single-molecule experiments are glucose oxidase and catalase (GOC) or protocatechuate dioxygenase (PCD). One of the pitfalls of these systems, however, is the production of carboxylic acids. These acids can result in a significant pH drop over the course of experiments and must thus be compensated by an increased buffer strength. Here, we present pyranose oxidase and catalase (POC) as a novel enzymatic system to perform single-molecule experiments in pH-stable conditions at arbitrary buffer strength. We show that POC keeps the pH stable over hours, while GOC and PCD cause an increasing acidity of the buffer system. We further verify in single-molecule fluorescence experiments that POC performs as good as the common oxygen-scavenging systems, but offers long-term pH stability and more freedom in buffer conditions. This enhanced stability allows the observation of bionanotechnological assemblies in aqueous environments under well-defined conditions for an extended time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Cited by
Optical tweezers in single-molecule biophysics
Bustamante, C. J., Chemla, Y. R., Liu, S., & Wang, M. D. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00021-6 · Cited by 615
Ultra-stable organic fluorophores for single-molecule research
Zheng, Q., Juette, M. F., Jockusch, S., Wasserman, M. R., Zhou, Z., Altman, R. B., & Blanchard, S. C. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60237k · Cited by 406
Photobleaching of organic fluorophores: quantitative characterization, mechanisms, protection *
Demchenko, A. P. (2020) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/ab7365 · Cited by 370
Switchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
Single-Molecule Fluorescence Spectroscopy of Photosynthetic Systems
Kondo, T., Chen, W. J., & Schlau-Cohen, G. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00195 · Cited by 120
Metadata
- Authors
- Swoboda, M., Henig, J., Cheng, H.-M., Brugger, D., Haltrich, D., Plumeré, N., & Schlierf, M.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-06-22
- Volume
- 6
- Issue
- 7
- Pages
- 6364-6369
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W1996641218
- Cited by
- 209
- References
- 1
- FWCI
- 4.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.