Investigation of Protein Detection Parameters Using Nanofunctionalized Organic Field-Effect Transistors
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Biodetection using organic field-effect transistors (OFETs) is gaining increasing interest for applications as diverse as food security, environmental monitoring, and medical diagnostics. However, there still lacks a comprehensive, empirical study on the fundamental limits of OFET sensors. In this paper, we present a thorough study of the various parameters affecting biosensing using an OFET decorated with gold nanoparticle (AuNP) binding sites. These parameters include the spacing between receptors, pH of the buffer, and ionic strength of the buffer. To this end, we employed the thrombin protein and its corresponding DNA binding aptamer to form our model detection system. We demonstrate a detection limit of 100 pM for this protein with high selectivity over other proteases in situ. We describe herein a feasible approach for protein detection with OFETs and a thorough investigation of parameters governing biodetection events using OFETs. Our obtained results should provide important guidelines to tailor the sensor's dynamic range to suit other desired OFET-based biodetection applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Dual‐Gate Organic Field‐Effect Transistors as Potentiometric Sensors in Aqueous Solution
Spijkman, M., Brondijk, J. J., Geuns, T. C. T., Smits, E. C. P., Cramer, T., Zerbetto, F., Stoliar, P., Biscarini, F., Blom, P. W. M., & de Leeuw, D. M. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200901830 · Cited by 154
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Self-citationOrganic field-effect transistor sensors: a tutorial review
Torsi, L., Magliulo, M., Manoli, K., & Palazzo, G. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60127g · Cited by 825
Flexible Organic Electronics in Biology: Materials and Devices
Liao, C., Zhang, M., Yao, M. Y., Hua, T., Li, L., & Yan, F. (2015) · Advanced Materials · doi:10.1002/adma.201402625 · Cited by 438
Chemical and Biomolecule Sensing with Organic Field-Effect Transistors
Li, H., Shi, W., Song, J., Jang, H.-J., Dailey, J., Yu, J., & Katz, H. E. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00016 · Cited by 424
Knopfmacher, O., Hammock, M. L., Appleton, A. L., Schwartz, G., Mei, J., Lei, T., Pei, J., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms3954 · Cited by 415
Self-citation
Metadata
- Authors
- Hammock, M. L., Knopfmacher, O., Naab, B. D., Tok, J. B.-H., & Bao, Z.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-04-25
- Volume
- 7
- Issue
- 5
- Pages
- 3970-3980
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2333294112
- Cited by
- 128
- References
- 3
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.