Beyond the Helix Pitch: Direct Visualization of Native DNA in Aqueous Solution
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The DNA double helix was first elucidated by J.D. Watson and F.H.C. Crick over a half century ago. However, no one could actually "see" the well-known structure ever. Among all real-space observation methods, only atomic force microscopy (AFM) enables us to visualize the biologically active structure of natural DNA in water. However, conventional AFM measurements often caused the structural deformation of DNA because of the strong interaction forces acting on DNA. Moreover, large contact area between the AFM probe and DNA hindered us from imaging sub-molecular-scale features smaller than helical periodicity of DNA. Here, we show the direct observation of native plasmid DNA in water using an ultra-low-noise AFM with the highly sensitive force detection method (frequency modulation AFM: FM-AFM). Our micrographs of DNA vividly exhibited not only overall structure of the B-form double helix in water but also local structures which deviate from the crystallographic structures of DNA without any damage. Moreover, the interaction force area in the FM-AFM was small enough to clearly discern individual functional groups within DNA. The technique was also applied to explore the synthesized DNA nanostructures toward the current nanobiotechnology. This work will be essential for considering the structure-function relationship of biomolecular systems in vivo and for in situ analysis of DNA-based nanodevices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Structure of Nucleic Acids: A Structure for Deoxyribose Nucleic Acid
WATSON, J. D., & CRICK, F. H. C. (1953) · Nature · doi:10.1038/171737a0 · Cited by 13,584
Design and self-assembly of two-dimensional DNA crystals
Winfree, E., Liu, F., Wenzler, L. A., & Seeman, N. C. (1998) · Nature · doi:10.1038/28998 · Cited by 2,857
Cited by
Yashima, E., Ousaka, N., Taura, D., Shimomura, K., Ikai, T., & Maeda, K. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00354 · Cited by 2,004
Imaging modes of atomic force microscopy for application in molecular and cell biology
Dufrêne, Y. F., Ando, T., Garcia, R., Alsteens, D., Martinez-Martin, D., Engel, A., Gerber, C., & Müller, D. J. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.45 · Cited by 945
Introducing improved structural properties and salt dependence into a coarse-grained model of DNA
Snodin, B. E. K., Randisi, F., Mosayebi, M., Šulc, P., Schreck, J. S., Romano, F., Ouldridge, T. E., Tsukanov, R., Nir, E., Louis, A. A., et al. (2015) · The Journal of Chemical Physics · doi:10.1063/1.4921957 · Cited by 381
Synthesis, Assembly, and Applications of Hybrid Nanostructures for Biosensing
Zhang, S., Geryak, R., Geldmeier, J., Kim, S., & Tsukruk, V. V. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00088 · Cited by 340
Atomic- and Molecular-Resolution Mapping of Solid–Liquid Interfaces by 3D Atomic Force Microscopy
Fukuma, T., & Garcia, R. (2018) · ACS Nano · doi:10.1021/acsnano.8b07216 · Cited by 198
Metadata
- Authors
- Ido, S., Kimura, K., Oyabu, N., Kobayashi, K., Tsukada, M., Matsushige, K., & Yamada, H.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-02-04
- Volume
- 7
- Issue
- 2
- Pages
- 1817-1822
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2316726441
- Cited by
- 141
- References
- 2
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.