The DOI matches its Crossref record.
Fluorescence Lifetime Imaging Microscopy for the Detection of Intracellular pH with Quantum Dot Nanosensors
Abstract
While the use of quantum dot (QD) nanoparticles for bioimaging and sensing has been improved and exploited during the last several years, most studies have used emission intensity-based techniques. Fluorescence lifetime imaging microscopy (FLIM) can also be employed for sensing purposes, overcoming many of the limitations of the aforementioned systems. Herein, we show that the photoluminescence (PL) lifetime of mercaptopropionic acid-capped QDs (MPA-QDs) collected from FLIM images can be used to determine intracellular pH. The PL average lifetime of MPA-QDs varied from 8.7 ns (pH < 5) to 15.4 ns (pH > 8) in media mimicking the intracellular environment. These long decay times of QD nanoparticles make them easily distinguishable from intrinsic cell autofluorescence, improving selectivity in sensing applications. We demonstrate, for the first time, the successful detection of changes in the intracellular pH of different cell types by examining the PL decay time of QDs. In particular, the combination of FLIM methodologies with QD nanoparticles exhibits greatly improved sensitivity compared with other fluorescent dyes for pH imaging. A detailed description of the advantages of the FLIM technique is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
An overview of nanoparticles commonly used in fluorescent bioimaging
Wolfbeis, O. S. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00392f · Cited by 1,631
Quantum dots: bright and versatile in vitro and in vivo fluorescence imaging biosensors
Wegner, K. D., & Hildebrandt, N. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00532e · Cited by 984
Long-Lived Emissive Probes for Time-Resolved Photoluminescence Bioimaging and Biosensing
Zhang, K. Y., Yu, Q., Wei, H., Liu, S., Zhao, Q., & Huang, W. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00425 · Cited by 923
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Magnetic particle hyperthermia—a promising tumour therapy?
Dutz, S., & Hergt, R. (2014) · Nanotechnology · doi:10.1088/0957-4484/25/45/452001 · Cited by 525
Metadata
- Authors
- Orte, A., Alvarez-Pez, J. M., & Ruedas-Rama, M. J.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-06-28
- Volume
- 7
- Issue
- 7
- Pages
- 6387-6395
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2033598218
- Cited by
- 194
- References
- 0
- FWCI
- 9.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence Lifetime Imaging Microscopy for the Detection of Intracellular pH with Quantum Dot Nanosensors. https://app.cochat.ai/papers/10.1021/nn402581q
- The paper
- Orte, A., Alvarez-Pez, J. M., & Ruedas-Rama, M. J. (2013). Fluorescence Lifetime Imaging Microscopy for the Detection of Intracellular pH with Quantum Dot Nanosensors. ACS Nano. https://doi.org/10.1021/nn402581q
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.