The DOI matches its Crossref record.
Nd3+-Sensitized Upconversion Nanophosphors: Efficient In Vivo Bioimaging Probes with Minimized Heating Effect
Abstract
Upconversion (UC) process in lanthanide-doped nanomaterials has attracted great research interest for its extensive biological applications in vitro and in vivo, benefiting from the high tissue penetration depth of near-infrared excitation light and low autofluorescence background. However, the 980 nm laser, typically used to trigger the Yb(3+)-sensitized UC process, is strongly absorbed by water in biological structures and could cause severe overheating effect. In this article, we report the extension of the UC excitation spectrum to shorter wavelengths, where water has lower absorption. This is realized by further introducing Nd(3+) as the sensitizer and by building a core/shell structure to ensure successive Nd(3+) → Yb(3+) → activator energy transfer. The efficacy of this Nd(3+)-sensitized UC process is demonstrated in in vivo imaging, and the results confirmed that the laser-induced local overheating effect is greatly minimized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
An overview of nanoparticles commonly used in fluorescent bioimaging
Wolfbeis, O. S. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00392f · Cited by 1,631
Temporal full-colour tuning through non-steady-state upconversion
Deng, R., Qin, F., Chen, R., Huang, W., Hong, M., & Liu, X. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2014.317 · Cited by 990
Zheng, W., Huang, P., Tu, D., Ma, E., Zhu, H., & Chen, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00178h · Cited by 894
Li, X., Zhang, F., & Zhao, D. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00163j · Cited by 615
Zhong, Y., Tian, G., Gu, Z., Yang, Y., Gu, L., Zhao, Y., Ma, Y., & Yao, J. (2014) · Advanced Materials · doi:10.1002/adma.201304903 · Cited by 448
Near‐Infrared‐Sensitive Materials Based on Upconverting Nanoparticles
Wu, S., & Butt, H. (2016) · Advanced Materials · doi:10.1002/adma.201502843 · Cited by 417
Shao, W., Chen, G., Kuzmin, A., Kutscher, H. L., Pliss, A., Ohulchanskyy, T. Y., & Prasad, P. N. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b08973 · Cited by 386
Sun, L.-D., Wang, Y.-F., & Yan, C.-H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400218t · Cited by 363
Self-citationTian, G., Zhang, X., Gu, Z., & Zhao, Y. (2015) · Advanced Materials · doi:10.1002/adma.201503280 · Cited by 278
Strategies to Improve Cancer Photothermal Therapy Mediated by Nanomaterials
de Melo‐Diogo, D., Pais‐Silva, C., Dias, D. R., Moreira, A. F., & Correia, I. J. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700073 · Cited by 267
Metadata
- Authors
- Wang, Y.-F., Liu, G.-Y., Sun, L.-D., Xiao, J.-W., Zhou, J.-C., & Yan, C.-H.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-07-23
- Volume
- 7
- Issue
- 8
- Pages
- 7200-7206
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W1967678184
- Cited by
- 883
- References
- 0
- FWCI
- 42.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.