The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fabrication of a Stretchable Solid-State Micro-Supercapacitor Array
Abstract
We fabricated a stretchable micro-supercapacitor array with planar SWCNT electrodes and an ionic liquid-based triblock copolymer electrolyte. The mechanical stability of the entire supercapacitor array upon stretching was obtained by adopting strategic design concepts. First, the narrow and long serpentine metallic interconnections were encapsulated with polyimide thin film to ensure that they were within the mechanical neutral plane. Second, an array of two-dimensional planar micro-supercapacitor with SWCNT electrodes and an ion-gel-type electrolyte was made to achieve all-solid-state energy storage devices. The formed micro-supercapacitor array showed excellent performances which were stable over stretching up to 30% without any noticeable degradation. This work shows the strong potential of a stretchable micro-supercapacitor array in applications such as wearable computers, power dressing, electronic newspapers, paper-like mobile phones, and other easily collapsible gadgets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, R.-H., Kim, D.-H., Xiao, J., Kim, B. H., Park, S.-I., Panilaitis, B., Ghaffari, R., Yao, J., Li, M., Liu, Z., et al. (2010) · Nature Materials · doi:10.1038/nmat2879 · Cited by 637
Self-citation
Cited by
Recent Advances in Flexible and Stretchable Bio‐Electronic Devices Integrated with Nanomaterials
Choi, S., Lee, H., Ghaffari, R., Hyeon, T., & Kim, D. (2016) · Advanced Materials · doi:10.1002/adma.201504150 · Cited by 1,104
Self-citationQi, D., Liu, Y., Liu, Z., Zhang, L., & Chen, X. (2017) · Advanced Materials · doi:10.1002/adma.201602802 · Cited by 470
Materials Design and System Construction for Conventional and New‐Concept Supercapacitors
Wu, Z., Li, L., Yan, J., & Zhang, X. (2017) · Advanced Science · doi:10.1002/advs.201600382 · Cited by 470
Stretchable Active Matrix Temperature Sensor Array of Polyaniline Nanofibers for Electronic Skin
Hong, S. Y., Lee, Y. H., Park, H., Jin, S. W., Jeong, Y. R., Yun, J., You, I., Zi, G., & Ha, J. S. (2016) · Advanced Materials · doi:10.1002/adma.201504659 · Cited by 454
Self-citationHarris, K. D., Elias, A. L., & Chung, H.-J. (2016) · Journal of Materials Science · doi:10.1007/s10853-015-9643-3 · Cited by 403
Materials and Structures for Stretchable Energy Storage and Conversion Devices
Xie, K., & Wei, B. (2014) · Advanced Materials · doi:10.1002/adma.201305919 · Cited by 396
Design Considerations for Unconventional Electrochemical Energy Storage Architectures
Vlad, A., Singh, N., Galande, C., & Ajayan, P. M. (2015) · Advanced Energy Materials · doi:10.1002/aenm.201402115 · Cited by 346
Stretchable all-solid-state supercapacitor with wavy shaped polyaniline/graphene electrode
Xie, Y., Liu, Y., Zhao, Y., Tsang, Y. H., Lau, S. P., Huang, H., & Chai, Y. (2014) · J. Mater. Chem. A · doi:10.1039/c4ta00734d · Cited by 317
Kim, D., Kim, D., Lee, H., Jeong, Y. R., Lee, S., Yang, G., Kim, H., Lee, G., Jeon, S., Zi, G., et al. (2016) · Advanced Materials · doi:10.1002/adma.201504335 · Cited by 148
Self-citation
Metadata
- Authors
- Kim, D., Shin, G., Kang, Y. J., Kim, W., & Ha, J. S.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-08-22
- Volume
- 7
- Issue
- 9
- Pages
- 7975-7982
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2322976405
- Cited by
- 273
- References
- 1
- FWCI
- 9.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.