The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Nanoparticle-Based Ratiometric and Self-Calibrated Fluorescent Thermometer for Single Living Cells
Abstract
The homeostasis of body temperature and energy balance is one of the major principles in biology. Nanoscale thermometry of aqueous solutions is a challenging but crucial technique to understand the molecular basis of this essential process. Here, we developed a ratiometric nanothermometer (RNT) for intracellular temperature measurement in real time. Both the thermosensitive fluorophore, β-diketonate chelate europium(III) thenoyltrifluoroacetonate, and the thermoinsensitive fluorophore, rhodamine 101, which was used as a self-reference, are embedded in a polymeric particle that protects the fluorophores from intracellular conditions. The ratiometric measurement of single RNT spots is independent of the displacement of the RNT along the z-axis. The temperature is therefore determined at the location of each RNT under an optical microscope regardless of the dynamic movement of living cells. As a demonstration of the spot-by-spot intracellular thermometry, we successfully followed the temperature change in individual RNT spots in a single cell together with the Ca(2+) burst induced by the Ca(2+) ionophore ionomycin. The temperature increases differently among different spots, implying heterogeneous heat production in the cell. We then show that, in some spots, the temperature gradually decreases, while in others it remains high. The average temperature elevation within a cell is positively correlated to the increase in Ca(2+), suggesting that the activity and/or number of heat sources are dependent on the Ca(2+) concentration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sensitivity of CaM Kinase II to the Frequency of Ca 2+ Oscillations
De Koninck, P., & Schulman, H. (1998) · Science · doi:10.1126/science.279.5348.227 · Cited by 1,269
Thermometry and Thermal Transport in Micro/Nanoscale Solid-State Devices and Structures
Cahill, D. G., Goodson, K., & Majumdar, A. (2002) · Journal of Heat Transfer · doi:10.1115/1.1454111 · Cited by 611
Cited by
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Plasmonic Heating of Nanostructures
Jauffred, L., Samadi, A., Klingberg, H., Bendix, P. M., & Oddershede, L. B. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00738 · Cited by 602
Lanthanides in Luminescent Thermometry
Brites, C. D. S., Millán, A., & Carlos, L. D. (2016) · Handbook on the Physics and Chemistry of Rare Earths · doi:10.1016/bs.hpcre.2016.03.005 · Cited by 536
Gutiérrez, M., Zhang, Y., & Tan, J.-C. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00980 · Cited by 351
A critique of methods for temperature imaging in single cells
Baffou, G., Rigneault, H., Marguet, D., & Jullien, L. (2014) · Nature Methods · doi:10.1038/nmeth.3073 · Cited by 265
Metadata
- Authors
- Takei, Y., Arai, S., Murata, A., Takabayashi, M., Oyama, K., Ishiwata, S., Takeoka, S., & Suzuki, M.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-12-24
- Volume
- 8
- Issue
- 1
- Pages
- 198-206
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W1967151576
- Cited by
- 232
- References
- 2
- FWCI
- 10.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Nanoparticle-Based Ratiometric and Self-Calibrated Fluorescent Thermometer for Single Living Cells. https://app.cochat.ai/papers/10.1021/nn405456e
- The paper
- Takei, Y., Arai, S., Murata, A., Takabayashi, M., Oyama, K., Ishiwata, S., Takeoka, S., & Suzuki, M. (2014). A Nanoparticle-Based Ratiometric and Self-Calibrated Fluorescent Thermometer for Single Living Cells. ACS Nano. https://doi.org/10.1021/nn405456e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.