The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Biaxially Stretchable, Integrated Array of High Performance Microsupercapacitors
Abstract
We report on the fabrication of a biaxially stretchable array of high performance microsupercapacitors (MSCs) on a deformable substrate. The deformable substrate is designed to suppress local strain applied to active devices by locally implanting pieces of stiff polyethylene terephthalate (PET) films within the soft elastomer of Ecoflex. A strain suppressed region is formed on the top surface of the deformable substrate, below which PET films are implanted. Active devices placed within this region can be isolated from the strain. Analysis of strain distribution by finite element method confirms that the maximum strain applied to MSC in the strain suppressed region is smaller than 0.02%, while that on the Ecoflex film is larger than 250% under both uniaxial strain of 70% and biaxial strain of 50%. The all-solid-state planar MSCs, fabricated with layer-by-layer deposited multiwalled carbon nanotube electrodes and patterned ionogel electrolyte of poly(ethylene glycol) diacrylate and 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide having high-potential windows, are dry-transferred onto the deformable substrate and electrically connected in series and parallel via embedded liquid metal interconnection and Ag nanowire contacts. Liquid metal interconnection, formed by injecting liquid metal into the microchannel embedded within the substrate, can endure severe strains and requires no additional encapsulation process. This formed MSC array exhibits high energy and power density of 25 mWh/cm(3) and 32 W/cm(3), and stable electrochemical performance up to 100% uniaxial and 50% biaxial stretching. The high output voltage of the MSC array is used to light micro-light-emitting diode (μ-LED) arrays, even under strain conditions. This work demonstrates the potential application of our stretchable MSC arrays to wearable and bioimplantable electronics with a self-powered system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citation
Cited by
Electrolyte selection for supercapacitive devices: a critical review
Pal, B., Yang, S., Ramesh, S., Thangadurai, V., & Jose, R. (2019) · Nanoscale Advances · doi:10.1039/c9na00374f · Cited by 1,317
Towards establishing standard performance metrics for batteries, supercapacitors and beyond
Noori, A., El-Kady, M. F., Rahmanifar, M. S., Kaner, R. B., & Mousavi, M. F. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00581h · Cited by 1,303
Qi, D., Liu, Y., Liu, Z., Zhang, L., & Chen, X. (2017) · Advanced Materials · doi:10.1002/adma.201602802 · Cited by 470
Stretchable Active Matrix Temperature Sensor Array of Polyaniline Nanofibers for Electronic Skin
Hong, S. Y., Lee, Y. H., Park, H., Jin, S. W., Jeong, Y. R., Yun, J., You, I., Zi, G., & Ha, J. S. (2016) · Advanced Materials · doi:10.1002/adma.201504659 · Cited by 454
Self-citationKim, D., Kim, D., Lee, H., Jeong, Y. R., Lee, S., Yang, G., Kim, H., Lee, G., Jeon, S., Zi, G., et al. (2016) · Advanced Materials · doi:10.1002/adma.201504335 · Cited by 148
Self-citation
Metadata
- Authors
- Lim, Y., Yoon, J., Yun, J., Kim, D., Hong, S. Y., Lee, S.-J., Zi, G., & Ha, J. S.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-10-30
- Volume
- 8
- Issue
- 11
- Pages
- 11639-11650
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2320154137
- Cited by
- 165
- References
- 1
- FWCI
- 5.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.