Boron Polylactide Nanoparticles Exhibiting Fluorescence and Phosphorescence in Aqueous Medium
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Difluoroboron dibenzoylmethane-polylactide, BF(2)dbmPLA, a biocompatible polymer-luminophore conjugate was fabricated as nanoparticles. Spherical particles <100 nm in size were generated via nanoprecipitation. Intense blue fluorescence, two-photon absorption, and long-lived room temperature phosphorescence (RTP) are retained in aqueous suspension. The nanoparticles were internalized by cells and visualized by fluorescence microscopy. Luminescent boron biomaterials show potential for imaging and sensing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tumor vascular permeability and the EPR effect in macromolecular therapeutics: a review
Maeda, H., Wu, J., Sawa, T., Matsumura, Y., & Hori, K. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00248-5 · Cited by 6,565
BODIPY Dyes and Their Derivatives: Syntheses and Spectroscopic Properties
Loudet, A., & Burgess, K. (2007) · Chemical Reviews · doi:10.1021/cr078381n · Cited by 5,238
Controlled Ring-Opening Polymerization of Lactide and Glycolide
Dechy-Cabaret, O., Martin-Vaca, B., & Bourissou, D. (2004) · Chemical Reviews · doi:10.1021/cr040002s · Cited by 2,257
Formulation of functionalized PLGA-PEG Nanoparticles for in vivo targeted drug delivery
Cheng, J., Teply, B. A., Sherifi, I., Sung, J., Luther, G., Gu, F. X., Levy-Nissenbaum, E., Radovic-Moreno, A. F., Langer, R., & Farokhzad, O. C. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.09.047 · Cited by 1,273
Alexis, F. (2005) · Polymer International · doi:10.1002/pi.1697 · Cited by 443
Auras, R., Harte, B., & Selke, S. (2004) · Journal of Applied Polymer Science · doi:10.1002/app.20148 · Cited by 190 · cited 1×
“Because PLA is permeable to oxygen, response times can be fast.(42,43)”
Gorczynski, J. L., Chen, J., & Fraser, C. L. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0530927 · Cited by 76 · cited 1×
“58 was applied to all data, as previously described.(47) UV vis spectra were recorded on a Hewlett-Packard 8453 diodearray spectrophotometer.”
Self-citation
Cited by
Room-temperature phosphorescence from organic aggregates
Zhao, W., He, Z., & Tang, B. Z. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-0223-z · Cited by 1,766
A dual-emissive-materials design concept enables tumour hypoxia imaging
Zhang, G., Palmer, G. M., Dewhirst, M. W., & Fraser, C. L. (2009) · Nature Materials · doi:10.1038/nmat2509 · Cited by 1,150
Self-citationOptical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
Excited State Modulation for Organic Afterglow: Materials and Applications
Xu, S., Chen, R., Zheng, C., & Huang, W. (2016) · Advanced Materials · doi:10.1002/adma.201602604 · Cited by 851
Abdollahi, A., Roghani-Mamaqani, H., Razavi, B., & Salami-Kalajahi, M. (2020) · ACS Nano · doi:10.1021/acsnano.0c07289 · Cited by 643
Metadata
- Authors
- Pfister, A., Zhang, G., Zareno, J., Horwitz, A. F., & Fraser, C. L.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-05-31
- Volume
- 2
- Issue
- 6
- Pages
- 1252-1258
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W1980788132
- Cited by
- 144
- References
- 7
- FWCI
- 4.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.