The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A dual-emissive-materials design concept enables tumour hypoxia imaging
Open accessAbstract
Luminescent materials are widely used for imaging and sensing owing to their high sensitivity, rapid response and facile detection by many optical technologies1. Typically materials must be chemically tailored to achieve intense, photostable fluorescence, oxygen-sensitive phosphorescence or dual emission for ratiometric sensing, often by blending two dyes in a matrix. Dual-emissive materials combining all of these features in one easily tunable molecular platform are desirable, but when fluorescence and phosphorescence originate from the same dye, it can be challenging to vary relative fluorescence/phosphorescence intensities for practical sensing applications. Heavy-atom substitution2 alone increases phosphorescence by a given, not variable amount. Here, we report a strategy for modulating fluorescence/phosphorescence for a single-component, dual-emissive, iodide-substituted difluoroboron dibenzoylmethane-poly(lactic acid) (BF2dbm(I)PLA) solid-state sensor material. This is accomplished through systematic variation of the PLA chain length in controlled solvent-free lactide polymerization3 combined with heavy-atom substitution2. We demonstrate the versatility of this approach by showing that films made from low-molecular-weight BF2dbm(I)PLA with weak fluorescence and strong phosphorescence are promising as ‘turn on’ sensors for aerodynamics applications4, and that nanoparticles fabricated from a higher-molecular-weight polymer with balanced fluorescence and phosphorescence intensities serve as ratiometric tumour hypoxia imaging agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hypoxia — a key regulatory factor in tumour growth
Harris, A. L. (2002) · Nature Reviews Cancer · doi:10.1038/nrc704 · Cited by 5,177
Tumor Hypoxia: Definitions and Current Clinical, Biologic, and Molecular Aspects
Hockel, M., & Vaupel, P. (2001) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/93.4.266 · Cited by 2,662
The Triplet State and Molecular Electronic Processes in Organic Molecules
Lower, S. K., & El-Sayed, M. A. (1966) · Chemical Reviews · doi:10.1021/cr60240a004 · Cited by 1,146
Cited by
Room-temperature phosphorescence from organic aggregates
Zhao, W., He, Z., & Tang, B. Z. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-0223-z · Cited by 1,766
Activating efficient phosphorescence from purely organic materials by crystal design
Bolton, O., Lee, K., Kim, H.-J., Lin, K. Y., & Kim, J. (2011) · Nature Chemistry · doi:10.1038/nchem.984 · Cited by 1,662
Triplet photosensitizers: from molecular design to applications
Zhao, J., Wu, W., Sun, J., & Guo, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35531d · Cited by 1,579
Zhao, W., He, Z., Lam, J. W. Y., Peng, Q., Ma, H., Shuai, Z., Bai, G., Hao, J., & Tang, B. Z. (2016) · Chem · doi:10.1016/j.chempr.2016.08.010 · Cited by 821
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Metadata
- Authors
- Zhang, G., Palmer, G. M., Dewhirst, M. W., & Fraser, C. L.
- Venue
- Nature Materials
- Published
- 2009-08-09
- Volume
- 8
- Issue
- 9
- Pages
- 747-751
- ISSN
- 1476-1122 (ISSN-L)
- 1476-4660
- OpenAlex
- W2019037012
- Cited by
- 1,150
- References
- 3
- FWCI
- 13.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A dual-emissive-materials design concept enables tumour hypoxia imaging. https://app.cochat.ai/papers/10.1038/nmat2509
- The paper
- Zhang, G., Palmer, G. M., Dewhirst, M. W., & Fraser, C. L. (2009). A dual-emissive-materials design concept enables tumour hypoxia imaging. Nature Materials. https://doi.org/10.1038/nmat2509
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.