The DOI matches its Crossref record.
Ionic Current Rectification, Breakdown, and Switching in Heterogeneous Oxide Nanofluidic Devices
Abstract
We investigate several ion transport behaviors in sub-20 nm nanofluidic channels consisting of heterogeneous oxide materials. By utilizing distinct isoelectric points of SiO2 and Al2O3 surfaces and photolithography to define the charge distribution, nanofluidic channels containing positively and negatively charged surfaces are created to form an abrupt junction. This method provides much more robust surface charges than previous approaches by surface chemical treatment. The fabricated nanofluidic diodes exhibit high rectification of ion current and achieve record-high rectification factors (ratio of forward current to reverse current) of over 300. The current-voltage property of the device follows the theoretical model quantitatively, except that at low ion concentrations the forward current degrades and the reverse current is greater than theoretical prediction, which can be attributed to access resistance and breakdown of water molecules. The breakdown effect characterized by a negative conductance followed by a rapid increase of current is observed in a double junction diode. The occurrence of the breakdown is found to be enhanced by the abruptness of the junction between the heterogeneous nanochannels. Finally, we demonstrate ionic switching in a three-terminal nanofluidic triode in which the ionic flow can be electrically regulated between different channel branches. The study provides insight into the ion transport behavior in nanofluidic devices containing heterogeneous surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanofluidics for osmotic energy conversion
Zhang, Z., Wen, L., & Jiang, L. (2021) · Nature Reviews Materials · doi:10.1038/s41578-021-00300-4 · Cited by 713
Bipolar membranes: A review on principles, latest developments, and applications
Pärnamäe, R., Mareev, S., Nikonenko, V., Melnikov, S., Sheldeshov, N., Zabolotskii, V., Hamelers, H. V. M., & Tedesco, M. (2021) · Journal of Membrane Science · doi:10.1016/j.memsci.2020.118538 · Cited by 610
Engineered voltage-responsive nanopores
Siwy, Z. S., & Howorka, S. (2010) · Chem. Soc. Rev. · doi:10.1039/b909105j · Cited by 500
Bioinspired smart asymmetric nanochannel membranes
Zhang, Z., Wen, L., & Jiang, L. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00688h · Cited by 477
Asymmetric Ion Transport through Ion-Channel-Mimetic Solid-State Nanopores
Guo, W., Tian, Y., & Jiang, L. (2013) · Accounts of Chemical Research · doi:10.1021/ar400024p · Cited by 449
Zhang, Z., Kong, X.-Y., Xiao, K., Liu, Q., Xie, G., Li, P., Ma, J., Tian, Y., Wen, L., & Jiang, L. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b09918 · Cited by 351
Review article: Fabrication of nanofluidic devices
Duan, C., Wang, W., & Xie, Q. (2013) · Biomicrofluidics · doi:10.1063/1.4794973 · Cited by 274
Metadata
- Authors
- Cheng, L.-J., & Guo, L. J.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-02-16
- Volume
- 3
- Issue
- 3
- Pages
- 575-584
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2092775415
- Cited by
- 207
- References
- 0
- FWCI
- 7.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.