The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Efficient and Simple Colorimetric Fluoride Ion Sensor Based on Receptors Having Urea and Thiourea Binding Sites
Abstract
[structure: see text] Novel colorimetric receptors for selective fluoride ion sensing containing anthraquinone as chromogenic signaling subunit and urea (N,N' '-(9,10-dihydro-9,10-dioxo-1,2-anthracenediyl)bis[N'-phenyl])/thiourea (N,N' '-(9,10-dihydro-9,10-dihydro-9,10-dioxo-1,2-antrhacenediyl)bis[N-phenyl]) binding sites have been reported. These receptors have shown no affinity for other halide ions (Cl-, Br-, and I- ions). Well-defined color change in the visible region of the spectrum was observed upon addition of fluoride ion in DMSO/CH3CN solution of the receptors 1 and 2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Artificial Organic Host Molecules for Anions
Schmidtchen, F. P., & Berger, M. (1997) · Chemical Reviews · doi:10.1021/cr9603845 · Cited by 1,788
Sapphyrins: Versatile Anion Binding Agents
Sessler, J. L., & Davis, J. M. (2001) · Accounts of Chemical Research · doi:10.1021/ar980117g · Cited by 578
Biochemistry of the Elemental Halogens and Inorganic Halides
Kirk, K. L. (1991) · Springer eBooks · doi:10.1007/978-1-4684-5817-6 · Cited by 351
J., D. L. J., Martínez‐Máñez, R., Sancenón, F., & Soto, J. (2002) · Tetrahedron Letters · doi:10.1016/s0040-4039(02)00363-5 · Cited by 156
The Hydrogen Bond in Sulphur-containing Compounds
Zuika, I. V., & Bankovskii, Y. A. (1973) · Russian Chemical Reviews · doi:10.1070/rc1973v042n01abeh002562 · Cited by 31
Zepik (2001) · doi:10.1002/1521-3773(20010105)40:1
Cited by
Gunnlaugsson, T., Glynn, M., Tocci (née Hussey), G. M., Kruger, P. E., & Pfeffer, F. M. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.08.017 · Cited by 1,257
Recognition and sensing of fluoride anion
Cametti, M., & Rissanen, K. (2009) · Chemical Communications · doi:10.1039/b902069a · Cited by 654
Metadata
- Authors
- Jose, D. A., Kumar, D. K., Ganguly, B., & Das, A.
- Venue
- Organic Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-09-01
- Volume
- 6
- Issue
- 20
- Pages
- 3445-3448
- ISSN
- 1523-7052 (ISSN-L)
- 1523-7060
- OpenAlex
- W2057632520
- Cited by
- 454
- References
- 7
- FWCI
- 9.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficient and Simple Colorimetric Fluoride Ion Sensor Based on Receptors Having Urea and Thiourea Binding Sites. https://app.cochat.ai/papers/10.1021/ol048829w
- The paper
- Jose, D. A., Kumar, D. K., Ganguly, B., & Das, A. (2004). Efficient and Simple Colorimetric Fluoride Ion Sensor Based on Receptors Having Urea and Thiourea Binding Sites. Organic Letters. https://doi.org/10.1021/ol048829w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.