The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
A Chemodosimeter for the Ratiometric Detection of Hydrazine Based on Return of ESIPT and Its Application in Live-Cell Imaging
Abstract
A probe based on 2-(2'-hydroxyphenyl) benzothiazole (HBT) has been synthesized and used for the ratiometric detection of hydrazine. The probe is designed in such a way that the excited state intramolecular proton transfer (ESIPT) of the HBT moiety gets blocked. The chemodosimetric approach of hydrazine to the probe results in the recovery of the ESIPT by removal of a free HBT moiety through subsequent substitution, cyclization, and elimination processes. The probe is successfully demonstrated to enable the detection of hydrazine in live cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90338-v · Cited by 7,112
KIRK-OTHMER ENCYCLOPEDIA OF CHEMICAL TECHNOLOGY
(1982) · Chemical & Engineering News Archive · doi:10.1021/cen-v060n014.ibc · Cited by 2,405
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Fluorescent Chemosensors Based on Spiroring-Opening of Xanthenes and Related Derivatives
Chen, X., Pradhan, T., Wang, F., Kim, J. S., & Yoon, J. (2012) · Chemical Reviews · doi:10.1021/cr200201z · Cited by 1,984
Fluoro- and Chromogenic Chemodosimeters for Heavy Metal Ion Detection in Solution and Biospecimens
Quang, D. T., & Kim, J. S. (2010) · Chemical Reviews · doi:10.1021/cr100154p · Cited by 1,355
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Zhang, J. F., Zhou, Y., Yoon, J., & Kim, J. S. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15028f · Cited by 826
A Rapid Aqueous Fluoride Ion Sensor with Dual Output Modes
Hu, R., Feng, J., Hu, D., Wang, S., Li, S., Li, Y., & Yang, G. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201000790 · Cited by 546
Synthetic methodology for alkyl substituted hydrazines
Ragnarsson, U. (2001) · Chemical Society Reviews · doi:10.1039/b010091a · Cited by 453
Human health perspective of environmental exposure to hydrazines: A review
Choudhary, G., & Hansen, H. (1998) · Chemosphere · doi:10.1016/s0045-6535(98)00088-5 · Cited by 311
IARC monographs on the Evaluation of Carcinogenic Risk of Chemicals to Humans
Salmon, A. G. (1985) · Occupational and Environmental Medicine · doi:10.1136/oem.42.3.214 · Cited by 274
Potential application of anion-exchange membrane for hydrazine fuel cell electrolyte
Yamada, K., Yasuda, K., Fujiwara, N., Siroma, Z., Tanaka, H., Miyazaki, Y., & Kobayashi, T. (2003) · Electrochemistry Communications · doi:10.1016/j.elecom.2003.08.015 · Cited by 260
Occupational exposure to hydrazines: treatment of acute central nervous system toxicity.
Zelnick, S. D., Mattie, D. R., & Stepaniak, P. C. (2003) · PubMed · Cited by 241
A Ratiometric Near-Infrared Fluorescent Probe for Hydrazine and Its in Vivo Applications
Hu, C., Sun, W., Cao, J., Gao, P., Wang, J., Fan, J., Song, F., Sun, S., & Peng, X. (2013) · Organic Letters · doi:10.1021/ol401838p · Cited by 216
An ICT-based ratiometric probe for hydrazine and its application in live cells
Fan, J., Sun, W., Hu, M., Cao, J., Cheng, G., Dong, H., Song, K., Liu, Y., Sun, S., & Peng, X. (2012) · Chemical Communications · doi:10.1039/c2cc34168a · Cited by 213
A “Reactive” Ratiometric Fluorescent Probe for Mercury Species
Santra, M., Roy, B., & Ahn, K. H. (2011) · Organic Letters · doi:10.1021/ol2011693 · Cited by 204
Hydrazine-Selective Chromogenic and Fluorogenic Probe Based on Levulinated Coumarin
Choi, M. G., Hwang, J., Moon, J. O., Sung, J., & Chang, S.-K. (2011) · Organic Letters · doi:10.1021/ol202136q · Cited by 180
A highly selective fluorescent ESIPT probe for the dual specificity phosphatase MKP-6
Kim, T., Kang, H. J., Han, G., Chung, S. J., & Kim, Y. (2009) · Chemical Communications · doi:10.1039/b911145j · Cited by 156
Maity, D., Kumar, V., & Govindaraju, T. (2012) · Organic Letters · doi:10.1021/ol302904c · Cited by 151
Development of a near-infrared fluorescent probe for monitoring hydrazine in serum and living cells
Zhu, S., Lin, W., & Yuan, L. (2013) · Analytical Methods · doi:10.1039/c3ay40540k · Cited by 123
Dual signaling of hydrazine by selective deprotection of dichlorofluorescein and resorufin acetates
Choi, M. G., Moon, J. O., Bae, J., Lee, J. W., & Chang, S. (2013) · Organic & Biomolecular Chemistry · doi:10.1039/c3ob40091c · Cited by 100
Metadata
- Authors
- Goswami, S., Das, S., Aich, K., Pakhira, B., Panja, S., Mukherjee, S. K., & Sarkar, S.
- Venue
- Organic Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-10-18
- Volume
- 15
- Issue
- 21
- Pages
- 5412-5415
- ISSN
- 1523-7052 (ISSN-L)
- 1523-7060
- OpenAlex
- W2021134836
- Cited by
- 253
- References
- 21
- FWCI
- 9.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.