The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Tuning the Selectivity of Two Chemosensors to Fe(III) and Cr(III)
Open accessAbstract
Two rhodamine-based chemosensors (1 and 2) were designed, and their sensing behavior toward metal ions was investigated by fluorescence spectroscopies. 1 and 2 achieved tuning the selectivity to Fe(III) and Cr(III) in 100% aqueous solution, whereas other ions including Cd(II), Co(II), Cu(II), Ni(II), Zn(II), Mg(II), Ba(II), Pb(II), Na(I), and K(I) induced basically no spectral change, which constituted a Fe(III)-selective and a Cr(III)-selective fluorescent chemosensor, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Molecular Fluorescence: Principles and Applications
Valeur, B. (2001) · Wiley eBooks · doi:10.1002/3527600248 · Cited by 1,931
Yang, Y.-K., Yook, K.-J., & Tae, J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054855t · Cited by 1,044
Chromium in the environment: factors affecting biological remediation
Zayed, A. M., & Terry, N. (2003) · Plant and Soil · doi:10.1023/a:1022504826342 · Cited by 959
Chemosensors of Ion and Molecule Recognition
(1997) · Springer eBooks · doi:10.1007/978-94-011-3973-1 · Cited by 488
Chemical Sensors and Biosensors for Medical and Biological Applications
Spichiger‐Keller, U. E. (1998) · Wiley eBooks · doi:10.1002/9783527612284 · Cited by 419
Highly Sensitive and Selective Chemosensor for Hg2+ Based on the Rhodamine Fluorophore
Lee, M. H., Wu, J.-S., Lee, J. W., Jung, J. H., & Kim, J. S. (2007) · Organic Letters · doi:10.1021/ol0708931 · Cited by 317
Highly Sensitive Fluorescent Probe for Selective Detection of Hg2+ in DMF Aqueous Media
Wu, D., Huang, W., Duan, C., Lin, Z., & Meng, Q. (2007) · Inorganic Chemistry · doi:10.1021/ic062274e · Cited by 289
The Rhodafluor Family. An Initial Study of Potential Ratiometric Fluorescent Sensors for Zn2+
Burdette, S. C., & Lippard, S. J. (2002) · Inorganic Chemistry · doi:10.1021/ic026048q · Cited by 122
A highly selective ‘off–on’ fluorescence chemosensor for Cr(III)
Sarkar, M., Banthia, S., & Samanta, A. (2006) · Tetrahedron Letters · doi:10.1016/j.tetlet.2006.08.091 · Cited by 119
Cited by
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Fluorescent Chemosensors Based on Spiroring-Opening of Xanthenes and Related Derivatives
Chen, X., Pradhan, T., Wang, F., Kim, J. S., & Yoon, J. (2012) · Chemical Reviews · doi:10.1021/cr200201z · Cited by 1,984
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Synthesis and applications of Rhodamine derivatives as fluorescent probes
Beija, M., Afonso, C. A. M., & Martinho, J. M. G. (2009) · Chemical Society Reviews · doi:10.1039/b901612k · Cited by 1,463
Iron(iii) selective molecular and supramolecular fluorescent probes
Sahoo, S. K., Sharma, D., Bera, R. K., Crisponi, G., & Callan, J. F. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35152h · Cited by 779
Metadata
- Authors
- Mao, J., Wang, L., Dou, W., Tang, X., Yan, Y., & Liu, W.
- Venue
- Organic Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-09-27
- Volume
- 9
- Issue
- 22
- Pages
- 4567-4570
- ISSN
- 1523-7052 (ISSN-L)
- 1523-7060
- OpenAlex
- W1970959274
- Cited by
- 380
- References
- 10
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.