The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Highly Selective Fluorescent Probe for Thiol Bioimaging
Abstract
A new fluorescent turn-on probe (3) for the selective sensing and bioimaging of thiols is reported. In aqueous buffer solutions at physiological pH, thiols cleave the 2,4-dinitrobenzenesulfonyl group to release the red-emissive donor-acceptor fluorophore (4). The probe displays excellent immunity to interference from nitrogen and oxygen nucleophiles and the imaging of thiols in living cells is demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Homocysteine and Cardiovascular Disease
Refsum, H., Ueland, P. M., Nygård, O., & Vollset, S. E. (1998) · Annual Review of Medicine · doi:10.1146/annurev.med.49.1.31 · Cited by 2,180
Cited by
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Li, H., Fan, J., Wang, J., Tian, M., Du, J., Sun, S., Sun, P., & Peng, X. (2009) · Chemical Communications · doi:10.1039/b907511a · Cited by 339
Thiol Reactive Probes and Chemosensors
Peng, H., Chen, W., Cheng, Y., Hakuna, L., Strongin, R., & Wang, B. (2012) · Sensors · doi:10.3390/s121115907 · Cited by 275
Metadata
- Authors
- Bouffard, J., Kim, Y., Swager, T. M., Weissleder, R., & Hilderbrand, S. A.
- Venue
- Organic Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-12-07
- Volume
- 10
- Issue
- 1
- Pages
- 37-40
- ISSN
- 1523-7052 (ISSN-L)
- 1523-7060
- OpenAlex
- W2070805541
- Cited by
- 275
- References
- 1
- FWCI
- 8.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Highly Selective Fluorescent Probe for Thiol Bioimaging. https://app.cochat.ai/papers/10.1021/ol702539v
- The paper
- Bouffard, J., Kim, Y., Swager, T. M., Weissleder, R., & Hilderbrand, S. A. (2008). A Highly Selective Fluorescent Probe for Thiol Bioimaging. Organic Letters. https://doi.org/10.1021/ol702539v
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.