Off-Line Coupling of High-Resolution Capillary Electrophoresis to MALDI-TOF and TOF/TOF MS
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
High-resolution capillary electrophoresis has been coupled to MALDI-TOF and TOF/TOF MS through off-line vacuum deposition onto standard stainless steel MALDI targets. This off-line approach allowed the decoupling of the separation from the MS analysis, thus allowing each to be independently optimized in terms of time. Using BSA tryptic digest as a model sample, the deposited streaks, roughly 100-microm wide, were first analyzed in the MS mode, consuming only a fraction of the sample. After data analysis, segments of the deposited trace, containing unidentified peptides, as well as several species chosen for sequence confirmation, were reanalyzed in the MS/MS mode using MALDI-TOF/TOF MS. Additionally, it is shown that the shot-to-shot reproducibility of the vacuum-deposited trace (5% RSD) is 1 order of magnitude lower than that found for the standard dried droplet method. Moreover, a linear dependence of signal intensities (relative to an internal standard) over 3 orders of magnitude was found for a peptide sample with concentrations ranging from 1 to 1000 nM. This paper demonstrates the potential of off-line coupling of high-resolution separations to MALDI-MS and MALDI-MS/MS using vacuum deposition for the analysis of complex peptide mixtures from protein digests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tong, W., Link, A., Eng, J. K., & Yates, J. R. (1999) · Analytical Chemistry · doi:10.1021/ac9901182 · Cited by 143
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Mass Spectral Analysis in Proteomics
Yates, J. R. (2004) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.33.111502.082538 · Cited by 326
Capillary electrophoresis – mass spectrometry: 15 years of developments and applications
Schmitt‐Kopplin, P., & Frommberger, M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305659 · Cited by 289
Krokhin, O. V., Craig, R., Spicer, V., Ens, W., Standing, K. G., Beavis, R. C., & Wilkins, J. A. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400031-mcp200 · Cited by 284
“trace vacuum deposition (22, 23), and a similar deposition From the ‡Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, R3T 2N2, Canada; and §Manitoba Centre for Proteomics, University of Manitoba, Winnipeg, MB, R3E 3P4, Canada Received, February 26, 2004, and in revised form, July 6, 2004 Publ…”
BackgroundMischak, H., Coon, J. J., Novak, J., Weissinger, E. M., Schanstra, J. P., & Dominiczak, A. F. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20205 · Cited by 193
“Subsequently, the polypeptides of interest can be analyzed with MALDI-TOF/TOF (Rejtar et al., 2002; Kolch et al., 2005).”
Metadata
- Authors
- Rejtar, T., Hu, P., Juhasz, P., Campbell, J. M., Vestal, M. L., Preisler, J., & Karger, B. L.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-02-20
- Volume
- 1
- Issue
- 2
- Pages
- 171-179
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W2005774156
- Cited by
- 115
- References
- 1
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Off-Line Coupling of High-Resolution Capillary Electrophoresis to MALDI-TOF and TOF/TOF MS. https://app.cochat.ai/papers/10.1021/pr015519o
- The paper
- Rejtar, T., Hu, P., Juhasz, P., Campbell, J. M., Vestal, M. L., Preisler, J., & Karger, B. L. (2002). Off-Line Coupling of High-Resolution Capillary Electrophoresis to MALDI-TOF and TOF/TOF MS. Journal of Proteome Research. https://doi.org/10.1021/pr015519o
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.