Theoretical and Experimental Prospects for Protein Identification Based Solely on Accurate Mass Measurement
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We discuss the theoretical and experimental potential and limitations of protein identification by mass measurement of proteolytic peptides and database searching. For peptides differing in composition by one (or two or three) amino acids, a surprisingly high number turn out to have isomers: 10% (or 29% or 53%), considering the 20 common amino acids with equal relative abundance. Even if isomers differing by leucine/isoleucine are excluded, the latter numbers are 14% and 38% those isomeric peptides cannot be distinguished based on mass alone, and tandem mass spectrometry and/or other additional constraints are needed. However, for nominally isobaric peptides, the mass accuracy and resolving power of broadband Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry theoretically and experimentally suffice to resolve virtually all peptide doublets differing by up to two amino acids including the smallest mass difference of 3.4 mDa. We demonstrate experimental resolution of another pair of peptides differing by 11 mDa, even when present in a complex mixture of hundreds of other peptides. Keywords: protein identification • FTMS • FT-ICR • FTICR • exact mass • accurate mass, elemental composition • chemical formula • peptide • protein database • mass resolving power • mass resolution • mutation • post-translational modification
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mutagenesis and Mapping of a Mouse Gene, Clock , Essential for Circadian Behavior
Vitaterna, M. H., King, D. P., Chang, A.-M., Kornhauser, J. M., Lowrey, P. L., McDonald, J. D., Dove, W. F., Pinto, L. H., Turek, F. W., & Takahashi, J. S. (1994) · Science · doi:10.1126/science.8171325 · Cited by 1,632
Cited by
Orbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514
Natural Organic Matter and the Event Horizon of Mass Spectrometry
Hertkorn, N., Frommberger, M., Witt, M., Koch, B. P., Schmitt-Kopplin, P., & Perdue, E. M. (2008) · Analytical Chemistry · doi:10.1021/ac800464g · Cited by 455
Precision proteomics: The case for high resolution and high mass accuracy
Mann, M., & Kelleher, N. L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0800788105 · Cited by 450
“Note that even perfect mass accuracy does not prevent misidentification of related peptide sequences that differ by amino acid exchanges but leave the chemical composition unchanged (28).”
High-Resolution Mass Spectrometers
Marshall, A. G., & Hendrickson, C. L. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112945 · Cited by 394
Self-citationHigh Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281
Self-citation
Metadata
- Authors
- He, F., Emmett, M. R., Håkansson, K., Hendrickson, C. L., & Marshall, A. G.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-12-10
- Volume
- 3
- Issue
- 1
- Pages
- 61-67
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W2012520364
- Cited by
- 75
- References
- 1
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.