The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Precision proteomics: The case for high resolution and high mass accuracy
Open accessAbstract
Proteomics has progressed radically in the last 5 years and is now on par with most genomic technologies in throughput and comprehensiveness. Analyzing peptide mixtures by liquid chromatography coupled to high-resolution mass spectrometry (LC-MS) has emerged as the main technology for in-depth proteome analysis whereas two-dimensional gel electrophoresis, low-resolution MALDI, and protein arrays are playing niche roles. MS-based proteomics is rapidly becoming quantitative through both label-free and stable isotope labeling technologies. The latest generation of mass spectrometers combines extremely high resolving power, mass accuracy, and very high sequencing speed in routine proteomic applications. Peptide fragmentation is mostly performed in low-resolution but very sensitive and fast linear ion traps. However, alternative fragmentation methods and high-resolution fragment analysis are becoming much more practical. Recent advances in computational proteomics are removing the data analysis bottleneck. Thus, in a few specialized laboratories, “precision proteomics” can now identify and quantify almost all fragmented peptide peaks. Huge challenges and opportunities remain in technology development for proteomics; thus, this is not “the beginning of the end” but surely “the end of the beginning.”
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We emphasize that MS-based data from high-accuracy14,15 MS instruments combined with subsequent high-stringency protein inference analysis provide definitive best-practice confirmation of protein identification and abundance.”
From A high-stringency blueprint of the human proteome (2020) · cites this paper as [15]
Citations
Cites
High resolution two-dimensional electrophoresis of proteins.
O'Farrell, P. (1975) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)41496-8 · Cited by 19,246 · cited 1×
“Two-dimensional (2D) gel electrophoresis was conceived more than 30 years ago (1).”
Ong, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574 · cited 1×
“Of the two most common forms, 15N labeling is usually used for microorganisms or small metazoan (38, 39) whereas stable isotope labeling in cell culture (SILAC) is mostly used for mammalian cells (40, 41).”
Self-citationA Model for Random Sampling and Estimation of Relative Protein Abundance in Shotgun Proteomics
Liu, H., Sadygov, R. G., & Yates, J. R. (2004) · Analytical Chemistry · doi:10.1021/ac0498563 · Cited by 2,500
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370 · cited 2×
“Another fragmentation method, electron transfer dissociation (ETD) (45)—a relative of electron capture dissociation (ECD) (46)—provides a fragmentation pattern complementary to the normal ion trap dissociation and has also now been coupled to highresolution ‘‘read out’’ in the orbitrap.”
Mass Spectrometry and Protein Analysis
Domon, B., & Aebersold, R. (2006) · Science · doi:10.1126/science.1124619 · Cited by 2,181 · cited 1×
“Current MALDI/TOF instruments have medium mass resolving power ( 15,000) for both intact MS and fragmentation spectra acquired on the tandem TOF/TOF instruments (21), except for the combination of MALDI with the LTQ-Orbitrap.”
Proteomic analysis of post-translational modifications
Mann, M., & Jensen, O. N. (2003) · Nature Biotechnology · doi:10.1038/nbt0303-255 · Cited by 2,134
Self-citationIshihama, Y., Oda, Y., Tabata, T., Sato, T., Nagasu, T., Rappsilber, J., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500061-mcp200 · Cited by 2,055 · cited 1×
“, peptides in the correct mass range for MS) (37) and does not depend on repeated targeting of the same peptide.”
Self-citationAn Automated Multidimensional Protein Identification Technology for Shotgun Proteomics
Wolters, D. A., Washburn, M. P., & Yates, J. R. (2001) · Analytical Chemistry · doi:10.1021/ac010617e · Cited by 1,819 · cited 1×
“In this ‘‘shotgun approach’’ (11), tens of thousands of peptides with very large dynamic range (i.”
Mass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572 · cited 1×
“Accuracy in Protein Quantitation: The End of One-Size-Fits-All One of the most important themes in current proteomics is the move toward quantitation (33).”
Self-citationOlsen, J. V., de Godoy, L. M. F., Li, G., Macek, B., Mortensen, P., Pesch, R., Makarov, A., Lange, O., Horning, S., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500030-mcp200 · Cited by 1,510 · cited 1×
“Sequencing Larger Peptides and Top-Down Proteomics Driven by interest in detecting combinations of posttranslational modifications and improving instrumentation (16, 47), momentum is building to increase the size of peptides or small proteins analyzed by LC-MS/MS.”
Self-citation
Research works printed but not linked: 1
- 10.1002/1615-9861(200108)1:8<927::aid-prot927>3.0.co;2-t · doi:10.1002/1615-9861(200108)1:8<927::aid-prot927>3.0.co;2-t
Cited by
Cox, J., & Mann, M. (2008) · Nature Biotechnology · doi:10.1038/nbt.1511 · Cited by 14,855
Self-citationAndromeda: A Peptide Search Engine Integrated into the MaxQuant Environment
Cox, J., Neuhauser, N., Michalski, A., Scheltema, R. A., Olsen, J. V., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr101065j · Cited by 5,500
Self-citationQuantitative Phosphoproteomics Reveals Widespread Full Phosphorylation Site Occupancy During Mitosis
Olsen, J. V., Vermeulen, M., Santamaria, A., Kumar, C., Miller, M. L., Jensen, L. J., Gnad, F., Cox, J., Jensen, T. S., Nigg, E. A., et al. (2010) · Science Signaling · doi:10.1126/scisignal.2000475 · Cited by 1,479
Self-citationProtein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Peterson, A. C., Russell, J. D., Bailey, D. J., Westphall, M. S., & Coon, J. J. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.020131 · Cited by 1,288
“identification (44, 55), post-translational modification site lo-”
Metadata
- Authors
- Mann, M., & Kelleher, N. L.
- Affiliations
- Max Planck Institute of Biochemistry (DE)
- University of Illinois Urbana-Champaign (US)
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2008-11-25
- Volume
- 105
- Issue
- 47
- Pages
- 18132-18138
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC2587563
- OpenAlex
- W2105889769
- Cited by
- 450
- References
- 58
- Citations by year
- 2026: 6 · 2025: 10 · 2024: 19 · 2023: 7 · 2022: 18 · 2021: 12 · 2020: 16 · 2019: 21 · 2018: 13 · 2017: 22 · 2016: 22 · 2015: 26 · 2014: 35 · 2013: 38 · 2012: 49
- FWCI
- 19.21
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Max Planck Institute for Plasma Physics (submittedVersion)
- Funders
- National Institute of General Medical Sciences (GM 067193-06, R01GM067193)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- high-resolution mass spectrometry, mass accuracy, peptide identification, quantitative proteomics, label-free quantification, stable isotope labeling, computational proteomics, liquid chromatography-mass spectrometry
- MeSH terms
- Mass Spectrometry, Reproducibility of Results, Proteomics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Precision proteomics: The case for high resolution and high mass accuracy. https://app.cochat.ai/papers/10.1073/pnas.0800788105
- The paper
- Mann, M., & Kelleher, N. L. (2008). Precision proteomics: The case for high resolution and high mass accuracy. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0800788105
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.