Eliminating the Interferences from TRIS Buffer and SDS in Protein Analysis by Fused-Droplet Electrospray Ionization Mass Spectrometry
The DOI matches its Crossref record.
Abstract
Multiply charged protein ions were detected from the solutions containing a high concentration of tris(hydroxymethyl) aminomethane buffer (TRIS) and sodium dodecyl sulfate (SDS) using fused-droplet electrospray ionization mass spectrometry (FD-ESI/MS). The sample aerosols were generated at ambient temperature with a pneumatic nebulizer commonly used to produce sample aerosols in an atmospheric pressure chemical ionization (APCI) source. The aerosols were carried by nitrogen gas to the tip of a capillary where charged methanol droplets had been continuously generated by electrospraying an acidic methanol solution. The neutral sample aerosols then fused with the charged methanol droplets and electrospray ionization proceeded from the newly formed fused droplets to generate multiply charged protein ions. Because of its low solubility in methanol, TRIS molecules (concentration as high as 1 M) were efficiently excluded from the newly formed droplets and the protein ion signals were detected and observed in the mass spectra. To remove the interferences from SDS, equal moles of positively charged cetyltrimethylammonium bromide (CTAB) was added into the SDS containing sample solution to form the dodecyl sulfate-cetyltrimethylammonium ion pair (DS-CTA). The DS-CTA ion pair has a low polarity and solubility in methanol and is excluded from the fused droplet. Protein ions were still detected from the solution containing 10(-2) M of SDS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ambient desorption ionization mass spectrometry
Venter, A., Nefliu, M., & Graham Cooks, R. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.01.010 · Cited by 552
Chen, H., Venter, A., & Cooks, R. G. (2006) · Chemical Communications · doi:10.1039/b602614a · Cited by 514
Shiea, J., Huang, M., HSu, H., Lee, C., Yuan, C., Beech, I., & Sunner, J. (2005) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2243 · Cited by 481
Self-citationWeston, D. J. (2010) · The Analyst · doi:10.1039/b925579f · Cited by 357
Ambient mass spectrometry: bringing MS into the “real world”
Alberici, R. M., Simas, R. C., Sanvido, G. B., Romão, W., Lalli, P. M., Benassi, M., Cunha, I. B. S., & Eberlin, M. N. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3808-3 · Cited by 340
Metadata
- Authors
- Shieh, I.-F., Lee, C.-Y., & Shiea, J.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-03-16
- Volume
- 4
- Issue
- 2
- Pages
- 606-612
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W2058287186
- Cited by
- 94
- References
- 0
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Eliminating the Interferences from TRIS Buffer and SDS in Protein Analysis by Fused-Droplet Electrospray Ionization Mass Spectrometry. https://app.cochat.ai/papers/10.1021/pr049765m
- The paper
- Shieh, I.-F., Lee, C.-Y., & Shiea, J. (2005). Eliminating the Interferences from TRIS Buffer and SDS in Protein Analysis by Fused-Droplet Electrospray Ionization Mass Spectrometry. Journal of Proteome Research. https://doi.org/10.1021/pr049765m
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.