CoChat

More than 100,000 Detectable Peptide Species Elute in Single Shotgun Proteomics Runs but the Majority is Inaccessible to Data-Dependent LC−MS/MS

Open access
Michalski, Annette, Cox, Juergen, Mann, Matthias · 2011 · Journal of Proteome Research

The DOI matches its Crossref record.

Abstract

Shotgun proteomics entails the identification of as many peptides as possible from complex mixtures. Here we investigate how many peptides are detectable by high resolution MS in standard LC runs of cell lysate and how many of them are accessible to data-dependent MS/MS. Isotope clusters were determined by MaxQuant and stringently filtered for charge states and retention times typical of peptides. This resulted in more than 100,000 likely peptide features, of which only about 16% had been targeted for MS/MS. Three instrumental attributes determine the proportion of additional peptides that can be identified: sequencing speed, sensitivity, and precursor ion isolation. In our data, an MS/MS scan rate of 25/s would be necessary to target all peptide features, but this drops to less than 17/s for reasonably abundant peptides. Sensitivity is a greater challenge, with many peptide features requiring long MS/MS injection times (>250 ms). The greatest limitation, however, is the generally low proportion of the target peptide ion intensity in the MS/MS selection window (the "precursor ion fraction" or PIF). Median PIF is only 0.14, making the peptides difficult to identify by standard MS/MS methods. Our results aid in developing strategies to further increase coverage in shotgun proteomics.

Overview

Integrity signals

Registry

Crossref · 10.1021/pr101060v

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Still being checked.

Cited by

Items 101–200 of 678

Metadata

Authors
Michalski, A., Cox, J., & Mann, M.
Affiliations
Max Planck Society (DE)
Corresponding author
Mann, Matthias
Venue
Journal of Proteome Research
Published
2011-04
Volume
10
Issue
4
Pages
1785-1793
ISSN
  • 1535-3893 (ISSN-L)
  • 1535-3907
OpenAlex
W2073371472
Cited by
685
References
0
Citations by year
2026: 25 · 2025: 46 · 2024: 30 · 2023: 32 · 2022: 35 · 2021: 41 · 2020: 38 · 2019: 44 · 2018: 36 · 2017: 51 · 2016: 58 · 2015: 61 · 2014: 65 · 2013: 53 · 2012: 46
FWCI
27.25
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • Journal of Proteome Research (publishedVersion)
  • PubMed (publishedVersion)
  • Max Planck Institute for Plasma Physics (submittedVersion)
  • Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, other-oa)
Funders
European Commission
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
shotgun proteomics, peptide identification, cell lysate, MaxQuant
MeSH terms
Amino Acid Sequence, Animals, Chromatography, Liquid, HeLa Cells, Humans, Ions, Isotopes, Molecular Sequence Data, Peptides, Proteins, Sensitivity and Specificity, Software, Proteomics, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.