The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly Robust, Automated, and Sensitive Online TiO2-Based Phosphoproteomics Applied To Study Endogenous Phosphorylation in Drosophila melanogaster
Abstract
Reversible protein phosphorylation ranks among the most important post-translational modifications, and elucidation of phosphorylation sites is essential to understand the regulation of key cellular processes such as signal transduction. Enrichment of phosphorylated peptides is a prerequisite for successful analysis due to their low stoichiometry, heterogeneity, and low abundance. Enrichment is often performed manually, which is inherently labor-intensive and a major hindrance in large-scale analyses. Automation of the enrichment method would vastly improve reproducibility and thereby facilitate 'high-throughput' phosphoproteomics research. Here, we describe a robust and automated online TiO 2-based two-dimensional chromatographic approach to selectively enrich phosphorylated peptides from digests of complete cellular lysates. We demonstrate method enhancement for both adsorption and desorption of phosphorylated peptides resulting in lower limits of detection. Phosphorylated peptides from a mere 500 attomole tryptic digest of a protein mixture were easily detected. With the combination of strong cation exchange chromatography with the online TiO 2 enrichment, 2152 phosphopeptides were enriched from 250 microg of protein originating for the cell lysate of Drosophila melanogaster S2 cells. This is a 4-fold improvement when compared to an enrichment strategy based solely on strong cation exchange/LC-MS. Phosphopeptide enrichment methods are intrinsically biased against relatively basic phosphopeptides. Analysis of the p I distributions of the enriched/detected phosphopeptides showed that the p I profile resembles that of a total Drosophila protein digest, revealing that the current described online procedure does not discriminate against either more acidic or basic phosphopeptides. However, careful comparison of our new and existing phosphopeptide enrichment techniques also reveal that, like many enrichment techniques, we are still far from comprehensive phosphoproteomics analyses, and we describe several factors that still require to be addressed. Still, as the online approach allows the complementary measurements of phosphopeptides and their nonphosphorylated counterparts in subsequent analyses, this method is well-suited for automated quantitative phosphoproteomics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Large-scale phosphorylation analysis of mouse liver
Villén, J., Beausoleil, S. A., Gerber, S. A., & Gygi, S. P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609836104 · Cited by 730
Cited by
Multiplex peptide stable isotope dimethyl labeling for quantitative proteomics
Boersema, P. J., Raijmakers, R., Lemeer, S., Mohammed, S., & Heck, A. J. R. (2009) · Nature Protocols · doi:10.1038/nprot.2009.21 · Cited by 1,357
Self-citationQuantitative mass spectrometry in proteomics: critical review update from 2007 to the present
Bantscheff, M., Lemeer, S., Savitski, M. M., & Kuster, B. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6203-4 · Cited by 801
The Lgr5 intestinal stem cell signature: robust expression of proposed quiescent ‘+4’ cell markers
Muñoz, J., Stange, D. E., Schepers, A. G., van de Wetering, M., Koo, B., Itzkovitz, S., Volckmann, R., Kung, K. S., Koster, J., Radulescu, S., et al. (2012) · The EMBO Journal · doi:10.1038/emboj.2012.166 · Cited by 772
Self-citationThe SCX/IMAC enrichment approach for global phosphorylation analysis by mass spectrometry
Villén, J., & Gygi, S. P. (2008) · Nature Protocols · doi:10.1038/nprot.2008.150 · Cited by 629
Analytical strategies for phosphoproteomics
Thingholm, T. E., Jensen, O. N., & Larsen, M. R. (2009) · PROTEOMICS · doi:10.1002/pmic.200800454 · Cited by 477
Metadata
- Authors
- Pinkse, M. W. H., Mohammed, S., Gouw, J. W., van Breukelen, B., Vos, H. R., & Heck, A. J. R.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-11-23
- Volume
- 7
- Issue
- 2
- Pages
- 687-697
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W2055152749
- Cited by
- 168
- References
- 1
- FWCI
- 10.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.