Heat Stabilization of the Tissue Proteome: A New Technology for Improved Proteomics
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
After tissue or body fluid sampling, proteases and other protein-modifying enzymes can rapidly change composition of the proteome. As a direct consequence, analytical results will reflect a mix of in vivo proteome and ex vivo degradation products. Vital information about the presampling state may be destroyed or distorted, leading to variation between samples and incorrect conclusions. Sample stabilization and standardization of sample handling can reduce or eliminate this problem. Here, a novel tissue stabilization system which utilizes a combination of heat and pressure under vacuum was used to stop degradation in mouse brain tissue immediately after sampling. It was found by biochemical assays that enzymatic activity was reduced to background levels in stabilized samples. Western blot analysis confirmed that post-translational phosphorylations of analyzed proteins were stable and conserved for up to 2 h at room temperature and that peptide extracts were devoid of abundant protein degradation fragments. The combination of reduced complexity and proteolytic inactivation enabled mass spectrometric identification of several neuropeptides and endogenous peptides including modified species at higher levels compared to nonstabilized samples. The tissue stabilizing system ensures reproducible and rapid inactivation of enzymes. Therefore, the system provides a powerful improvement to proteomics by greatly reducing the complexity and dynamic range of the proteome in tissue samples and enables enhanced possibilities for discovery and analysis of clinically relevant protein/peptide biomarkers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Cited by
Norris, J. L., & Caprioli, R. M. (2013) · Chemical Reviews · doi:10.1021/cr3004295 · Cited by 696
Mass Spectrometric Imaging for Biomedical Tissue Analysis
Chughtai, K., & Heeren, R. M. A. (2010) · Chemical Reviews · doi:10.1021/cr100012c · Cited by 652
Proteomics: a pragmatic perspective
Mallick, P., & Kuster, B. (2010) · Nature Biotechnology · doi:10.1038/nbt.1658 · Cited by 430
Bekker-Jensen, D. B., Martínez-Val, A., Steigerwald, S., Rüther, P., Fort, K. L., Arrey, T. N., Harder, A., Makarov, A., & Olsen, J. V. (2020) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir119.001906 · Cited by 425
High-throughput and high-sensitivity phosphoproteomics with the EasyPhos platform
Humphrey, S. J., Karayel, O., James, D. E., & Mann, M. (2018) · Nature Protocols · doi:10.1038/s41596-018-0014-9 · Cited by 358
Quantitative maps of protein phosphorylation sites across 14 different rat organs and tissues
Lundby, A., Secher, A., Lage, K., Nordsborg, N. B., Dmytriyev, A., Lundby, C., & Olsen, J. V. (2012) · Nature Communications · doi:10.1038/ncomms1871 · Cited by 343
Kwiatkowski, M., Wurlitzer, M., Krutilin, A., Kiani, P., Nimer, R., Omidi, M., Mannaa, A., Bussmann, T., Bartkowiak, K., Kruber, S., et al. (2016) · Journal of Proteomics · doi:10.1016/j.jprot.2015.12.029 · Cited by 43
Loss of correlations among proteins in brains of the Ts65Dn mouse model of down syndrome
Ahmed, M. M., Sturgeon, X., Ellison, M., Davisson, M. T., & Gardiner, K. J. (2012) · Journal of Proteome Research · doi:10.1021/pr2011582 · Cited by 39
Metadata
- Authors
- Svensson, M., Borén, M., Sköld, K., Fälth, M., Sjögren, B., Andersson, M., Svenningsson, P., & Andrén, P. E.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-01-21
- Volume
- 8
- Issue
- 2
- Pages
- 974-981
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W1987692848
- Cited by
- 149
- References
- 1
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.