The DOI matches its Crossref record.
UPLC-MS-Based Analysis of Human Plasma for Metabonomics Using Solvent Precipitation or Solid Phase Extraction
Abstract
A study of the factors involved in obtaining valid global metabolite profiles from the LC-MS of human plasma for the purposes of metabonomic analysis has been undertaken. Plasma proteins were either precipitated with 3 vol of organic solvent (methanol or acetonitrile) or subjected to solid phase extraction (SPE) on a C18-bonded phase. For chromatography, a reversed-phase gradient system, based on acidified water/methanol, was used. Ultra performance liquid chromatography (UPLC) was performed on a C18-bonded stationary phase using sub 2 microm particles packed into a 2.1 x 100 mm column. The eluent from the column was subjected to analysis by positive electrospray ionization using a time-of-flight mass spectrometer. To obtain reproducible results for solvent-precipitated plasma, the "conditioning" of the system with injections of matrix prior to the main analytical run was essential. The repeatability of the methodology was improved significantly when the sample preparation was performed using solid phase extraction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Human Serum Metabolome (HUSERMET) Consortium, Dunn, W. B., Broadhurst, D., Begley, P., Zelena, E., Francis-McIntyre, S., Anderson, N., Brown, M., Knowles, J. D., Halsall, A., et al. (2011) · Nature Protocols · doi:10.1038/nprot.2011.335 · Cited by 3,294
Self-citationBroadhurst, D., Goodacre, R., Reinke, S. N., Kuligowski, J., Wilson, I. D., Lewis, M. R., & Dunn, W. B. (2018) · Metabolomics · doi:10.1007/s11306-018-1367-3 · Cited by 900
Self-citationDunn, W. B., Broadhurst, D. I., Atherton, H. J., Goodacre, R., & Griffin, J. L. (2011) · Chem. Soc. Rev. · doi:10.1039/b906712b · Cited by 860
Cajka, T., & Fiehn, O. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04491 · Cited by 830
Comprehensive analysis of lipids in biological systems by liquid chromatography-mass spectrometry
Cajka, T., & Fiehn, O. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.04.017 · Cited by 650
Emwas, A.-H. M. (2015) · Methods in Molecular Biology · doi:10.1007/978-1-4939-2377-9_13 · Cited by 610
Vuckovic, D. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6039-y · Cited by 532
Current practice of liquid chromatography–mass spectrometry in metabolomics and metabonomics
Gika, H. G., Theodoridis, G. A., Plumb, R. S., & Wilson, I. D. (2014) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2013.06.032 · Cited by 442
Self-citationDunn, W. B., Wilson, I. D., Nicholls, A. W., & Broadhurst, D. (2012) · Bioanalysis · doi:10.4155/bio.12.204 · Cited by 442
Self-citationEffects of pre-analytical processes on blood samples used in metabolomics studies
Yin, P., Lehmann, R., & Xu, G. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8565-x · Cited by 278
Preanalytical Aspects and Sample Quality Assessment in Metabolomics Studies of Human Blood
Yin, P., Peter, A., Franken, H., Zhao, X., Neukamm, S. S., Rosenbaum, L., Lucio, M., Zell, A., Häring, H.-U., Xu, G., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2012.199257 · Cited by 272
Masson, P., Alves, A. C., Ebbels, T. M. D., Nicholson, J. K., & Want, E. J. (2010) · Analytical Chemistry · doi:10.1021/ac101722e · Cited by 173
Guo, B., Chen, B., Liu, A., Zhu, W., & Yao, S. (2012) · Current Drug Metabolism · doi:10.2174/138920012803341401 · Cited by 80
Barri, T., Holmer-Jensen, J., Hermansen, K., & Dragsted, L. O. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.12.065 · Cited by 57
Metadata
- Authors
- Michopoulos, F., Lai, L., Gika, H., Theodoridis, G., & Wilson, I.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-02-23
- Volume
- 8
- Issue
- 4
- Pages
- 2114-2121
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W2086952823
- Cited by
- 177
- References
- 0
- FWCI
- 6.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.