Correlation between y-Type Ions Observed in Ion Trap and Triple Quadrupole Mass Spectrometers
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Multiple reaction monitoring mass spectrometry (MRM-MS) is a technique for high-sensitivity targeted analysis. In proteomics, MRM-MS can be used to monitor and quantify a peptide based on the production of expected fragment peaks from the selected peptide precursor ion. The choice of which fragment ions to monitor in order to achieve maximum sensitivity in MRM-MS can potentially be guided by existing MS/MS spectra. However, because the majority of discovery experiments are performed on ion trap platforms, there is concern in the field regarding the generalizability of these spectra to MRM-MS on a triple quadrupole instrument. In light of this concern, many operators perform an optimization step to determine the most intense fragments for a target peptide on a triple quadrupole mass spectrometer. We have addressed this issue by targeting, on a triple quadrupole, the top six y-ion peaks from ion trap-derived consensus library spectra for 258 doubly charged peptides from three different sample sets and quantifying the observed elution curves. This analysis revealed a strong correlation between the y-ion peak rank order and relative intensity across platforms. This suggests that y-type ions obtained from ion trap-based library spectra are well-suited for generating MRM-MS assays for triple quadrupoles and that optimization is not required for each target peptide.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
Anderson, L., & Hunter, C. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500331-mcp200 · Cited by 1,230
Desiere, F. (2006) · Nucleic Acids Research · doi:10.1093/nar/gkj040 · Cited by 910
Tai, S. S.-C., Bunk, D. M., White, & Welch, M. J. (2004) · Analytical Chemistry · doi:10.1021/ac049516h · Cited by 88
Cited by
Selected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions
Picotti, P., & Aebersold, R. (2012) · Nature Methods · doi:10.1038/nmeth.2015 · Cited by 1,302
The Skyline ecosystem: Informatics for quantitative mass spectrometry proteomics
Pino, L. K., Searle, B. C., Bollinger, J. G., Nunn, B., MacLean, B., & MacCoss, M. J. (2020) · Mass Spectrometry Reviews · doi:10.1002/mas.21540 · Cited by 800
Targeted Quantitation of Proteins by Mass Spectrometry
Liebler, D. C., & Zimmerman, L. J. (2013) · Biochemistry · doi:10.1021/bi400110b · Cited by 363
MacLean, B., Tomazela, D. M., Abbatiello, S. E., Zhang, S., Whiteaker, J. R., Paulovich, A. G., Carr, S. A., & MacCoss, M. J. (2010) · Analytical Chemistry · doi:10.1021/ac102179j · Cited by 238
Eshghi, A., Pistawka, A. J., Liu, J., Chen, M., Sinclair, N. J. T., Hardie, D. B., Elliott, M., Chen, L., Newman, R., Mohammed, Y., et al. (2020) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir119.001820 · Cited by 51
“The selection criteria used for selecting the three transitions included prioritizing y-ions over b-ions, because the former is more robustly fragmented in low-energy CID used in a triple quadrupole mass spectrometer (37), selecting the highest-intensity product ions to maximize sensitivity, and selecting transitions…”
Background
Metadata
- Authors
- Sherwood, C. A., Eastham, A., Lee, L. W., Risler, J., Vitek, O., & Martin, D. B.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-08-12
- Volume
- 8
- Issue
- 9
- Pages
- 4243-4251
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W1965017740
- Cited by
- 53
- References
- 3
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.