Cited by 88Thyroid Disorders and TreatmentsClinical Laboratory Practices and Quality ControlScientific Measurement and Uncertainty Evaluation

Development and evaluation of a reference measurement procedure for the determination of total 3,3',5-triiodothyronine in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry

Tai, Susan S.-C., Bunk, David M., White, Welch, Michael J.·2004·Analytical Chemistry

Abstract

3,3',5-Triiodothyronine (T3) is an important diagnostic marker for thyroid function. A reference measurement procedure (RMP) for total T3 in serum involving isotope dilution coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. The method uses solid-phase extraction with mixed-mode retention mechanisms of reversed phase and ion exchange prior to reversed-phase LC/MS/MS. In addition to a labeled T3 internal standard (T3-13C9), labeled thyroxine (T4-d5) is also added to serum samples in order to monitor the degradation of T4 to T3. The accuracy of the measurement was evaluated by a recovery study for added T3 and was supported by a comparison study with the other RMP. The recovery of the added T3 ranged from 98.9% to 99.4%. The results of this method and the other RMP agreed to within 1%. Samples of frozen serum pools were prepared and measured in three separate sets. Excellent reproducibility was obtained with within-set coefficients of variation (CVs) ranging from 0.8% to 1.6% and between-set CVs ranging from 1.9% to 2.6%. Excellent linearity was also obtained with correlation coefficients of all linear regression lines (measured intensity ratios vs mass ratios) ranging from 0.9995 to 0.9996. The detection limit at a signal-to-noise ratio of approximately 3 was 1 pg of T3. The T4 degradation during sample preparation was minimized to a small percentage (no more than 3% of the T3 values) by use of antioxidants (asco…

Integrity signals

Registry

Crossref · 10.1021/ac049516h

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Several laboratories have developed procedures to accurately determine total T4 and total T3 in human plasma or serum and largely agree on concentration ranges, but this consensus has not been achieved for most other TH metabolites.

    “While meanwhile several laboratories developed procedures to accurately determine total T4 and total T3 in human plasma or serum and largely agree on concentrations ranges (25, 67–73), this consensus has not been achieved yet for most of the other TH metabolites, which occur at much lower concentrations.”

Cited by

Sorted by citations

Authors
Tai, S. S.-C., Bunk, D. M., White, & Welch, M. J.
Affiliations
National Institute of Standards and Technology (US)
Corresponding author
Tai, Susan S.-C.
Venue
Analytical Chemistry
Published
2004-08-05
Volume
76
Issue
17
Pages
5092-5096
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2094539668
Cited by
88
References
0
Citations by year
2026: 1 · 2025: 4 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 1 · 2020: 8 · 2019: 2 · 2018: 1 · 2017: 4 · 2016: 5 · 2015: 3 · 2014: 6 · 2013: 5 · 2012: 2
FWCI
2.72
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Standards and Technology
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
Keywords
reverse T3, total T3, reference measurement procedure, isotope dilution, liquid chromatography-tandem mass spectrometry, solid-phase extraction, thyroxine to triiodothyronine conversion, human serum, method evaluation, recovery studies
MeSH terms
Chromatography, Liquid, Freezing, Humans, Reference Standards, Mass Spectrometry, Triiodothyronine, Reverse, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review