CoChat

Combination of Improved 18O Incorporation and Multiple Reaction Monitoring: A Universal Strategy for Absolute Quantitative Verification of Serum Candidate Biomarkers of Liver Cancer

Zhao, Yan, Jia, Wei, Sun, Wei, Jin, Wenhai, Guo, Lihai, Wei, Junying, Ying, Wantao, Zhang, Yangjun, Xie, Yongming, Jiang, Ying, He, Fuchu, Qian, Xiaohong · 2010 · Journal of Proteome Research
Cited by 82

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Stable isotope dilution-multiple reaction monitoring-mass spectrometry (SID-MRM-MS), which is an alternative to immunoassay methods such as ELISA and Western blotting, has been used to alleviate the bottlenecks of high-throughput verification of biomarker candidates recently. However, the inconvenience and high isotope consumption required to obtain stably labeled peptide impedes the broad application of this method. In our study, the (18)O-labeling method was introduced to generate stable isotope-labeled peptides instead of the Fmoc chemical synthesis and Qconcat recombinant protein synthesis methods. To make (18)O-labeling suitable for absolute quantification, we have added the following procedures: (1) RapiGest SF and microwave heating were added to increase the labeling efficiency; (2) trypsin was deactivated completely by chemical modification using tris(2-carboxyethyl)phosphine (TCEP) and iodoacetamide (IAA) to prevent back-exchange of (18)O to (16)O, and (3) MRM parameters were optimized to maximize specificity and better distinguish between (18)O-labeled and unlabeled peptides. As a result, the (18)O-labeled peptides can be prepared in less than 1 h with satisfactory efficiency (>97%) and remained stable for 1 week, compared to traditional protocols that require 5 h for labeling with poor stability. Excellent separation of (18)O-labeled and unlabeled peptides was achieved by the MRM-MS spectrum. Finally, through the combined improvement in (18)O-labeling with multiple reaction monitoring, an absolute quantification strategy was developed to quantitatively verify hepatocellular carcinoma-related biomarker candidates, namely, vitronectin and clusterin, in undepleted serum samples. Sample preparation and capillary-HPLC analysis were optimized for high-throughput applications. The reliability of this strategy was further evaluated by method validation, with accuracy (%RE) and precision (%RSD) of less than 20% and good linearity (r(2) > 0.99), and clinical validation, which were consistent with previously reported results. In summary, our strategy can promote broader application of SID-MRM-MS for biomarkers from discovery to verification regarding the significant advantages of the convenient and flexible generation of internal standards, the reduction in the sample labeling steps, and the simple transition.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/pr9011969

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 82

Metadata

Authors
Zhao, Y., Jia, W., Sun, W., Jin, W., Guo, L., Wei, J., Ying, W., Zhang, Y., Xie, Y., Jiang, Y., He, F., & Qian, X.
Venue
Journal of Proteome Research
Published
2010-05-10
Volume
9
Issue
6
Pages
3319-3327
ISSN
  • 1535-3893 (ISSN-L)
  • 1535-3907
OpenAlex
W2062904619
Cited by
82
References
5
FWCI
3.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.