The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Negative Ion Tandem Mass Spectrometry for the Detection of Glutathione Conjugates
Abstract
Characterization of S-linked conjugates of the endogenous tripeptide glutathione (gamma-glutamyl-cysteinylglycine, GSH) represents a valuable indirect approach for the identification of chemically reactive, electrophilic intermediates formed during the metabolism of both foreign compounds and endogenous substances. In most cases, GSH adducts generated in vitro or excreted in the bile of animals are detected by the use of liquid chromatography-tandem mass spectrometry (LC-MS/MS), employing survey scans based on characteristic fragmentations of this class of conjugates. However, a limitation of current LC-MS/MS approaches, which typically employ electrospray ionization with analysis of positive ions, is that no single survey scan exhibits broad utility in the detection of unknown GSH adducts, since different structural classes of conjugate (aromatic, benzylic, aliphatic, thioester, etc.) behave differently upon collision-induced dissociation (CID) of the respective [M + H]+ parent ions. In the present study, we evaluated MS/MS in the negative ion mode as an alternative approach and report herein that the spectra obtained by CID of the [M - H]- ions of a number of representative GSH adducts, as well as GSH itself, are dominated by fragments originating from the glutathionyl moiety of the tripeptide. In particular, the anion at m/z 272, corresponding nominally to deprotonated gamma-glutamyl-dehydroalanyl-glycine, was abundant in the negative ion spectra of free GSH and all GSH conjugates examined, suggesting that scanning for precursors of this ion may provide a generally applicable technique for the detection of adducts of unknown structure. The utility of this novel detection strategy was demonstrated in a series of in vitro and in vivo experiments where compounds known to undergo metabolic activation were examined for their propensity to form conjugates with GSH. In all cases, scanning for precursors of m/z 272 in the negative ion mode revealed the presence of the expected adducts and in some instances revealed additional conjugates that had not been reported previously. Positive ion MS/MS, on the other hand, was more useful than the corresponding negative ion scans in providing information on the molecular structure of GSH conjugates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kassahun, K., Pearson, P. G., Tang, W., McIntosh, I., Leung, K., Elmore, C., Dean, D., Wang, R., Doss, G., & Baillie, T. A. (2001) · Chemical Research in Toxicology · doi:10.1021/tx000180q · Cited by 311
Self-citation
Cited by
Zhang, H., Zhang, D., Ray, K., & Zhu, M. (2009) · Journal of Mass Spectrometry · doi:10.1002/jms.1610 · Cited by 294
Jaeschke, G., Kolczewski, S., Spooren, W., Vieira, E., Bitter-Stoll, N., Boissin, P., Borroni, E., Büttelmann, B., Ceccarelli, S., Clemann, N., et al. (2015) · Journal of Medicinal Chemistry · doi:10.1021/jm501642c · Cited by 66
Metadata
- Authors
- Dieckhaus, C. M., Fernández-Metzler, C. L., King, R., Krolikowski, P. H., & Baillie, T. A.
- Venue
- Chemical Research in Toxicology
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-03-09
- Volume
- 18
- Issue
- 4
- Pages
- 630-638
- ISSN
- 0893-228X (ISSN-L)
- 1520-5010
- OpenAlex
- W2045786384
- Cited by
- 220
- References
- 1
- FWCI
- 6.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Negative Ion Tandem Mass Spectrometry for the Detection of Glutathione Conjugates. https://app.cochat.ai/papers/10.1021/tx049741u
- The paper
- Dieckhaus, C. M., Fernández-Metzler, C. L., King, R., Krolikowski, P. H., & Baillie, T. A. (2005). Negative Ion Tandem Mass Spectrometry for the Detection of Glutathione Conjugates. Chemical Research in Toxicology. https://doi.org/10.1021/tx049741u
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.