CoChat

Identification of the Highly Reactive Cysteine 151 in the Chemopreventive Agent-Sensor Keap1 Protein is Method-Dependent

Eggler, Aimee L., Luo, Yan, van Breemen, Richard B., Mesecar, Andrew D. · 2007 · Chemical Research in Toxicology
Cited by 79

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Upregulation of cytoprotective and detoxifying enzyme expression by small molecules is emerging as an important means of preventing carcinogenesis as well as other diseases. A proposed target of these agents is the Kelch-like ECH-associated protein 1 (Keap1). The vast majority of these agents contain electrophilic moieties, which react with a subset of the 27 cysteines of human Keap1. Modification of these cysteines is proposed to result in nuclear accumulation of transcription factor NF-E2-related factor-2 (Nrf2), a Keap1 binding partner, leading to upregulation of cytoprotective enzymes. The electrophilic agent biotinylated iodoacetamide (BIA) has been used by different laboratories to determine the most reactive cysteines in human Keap1, and the different methods used have generated very different results. In particular, our group has found C151 of human Keap1 to be highly reactive, while others have not identified this cysteine as being even weakly reactive. Nevertheless, C151 is the only cysteine of Keap1 shown thus far in the cell environment to be required to sense chemopreventive agents. In this work, we show that the BIA-modified C151 tryptic peptide is reproducibly detected by our method. We also investigated the key differences in the methods that have been used to prepare the protein for modification by BIA. Removal of the reducing agent from Keap1 before the addition of BIA did not significantly change the modification pattern of Keap1. However, treatment of Keap1 using an ultracentrifugation device in one method resulted in approximately 99% of the protein remaining bound to the device at the time of BIA addition. In addition, the resulting pattern of cysteines identified as modified by BIA differed significantly from that obtained by our method. Notably, C151 was no longer detected as modified by BIA. We therefore recommend our method of Keap1 protein preparation for the detection of modified cysteines in proteomic studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/tx700217c

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 79

Metadata

Authors
Eggler, A. L., Luo, Y., van Breemen, R. B., & Mesecar, A. D.
Venue
Chemical Research in Toxicology
Published
2007-10-13
Volume
20
Issue
12
Pages
1878-1884
ISSN
  • 0893-228X (ISSN-L)
  • 1520-5010
OpenAlex
W2050599166
Cited by
79
References
5
FWCI
3.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.