Immunoaffinity/Gas Chromatography/High-Resolution Mass Spectrometry Method for the Detection of N2,3-Ethenoguanine
The DOI matches its Crossref record.
Abstract
Etheno adducts are formed after exposure to a number of carcinogens, including vinyl chloride, as well as endogenously as a result of lipid peroxidation. A sensitive and selective assay for N(2), 3-ethenoguanine (epsilonGua) was developed using immunoaffinity (IA) columns made with polyclonal antibodies to epsilonGua followed by gas chromatography/electron capture negative chemical ionization/high-resolution mass spectrometry (GC/ECNCI/HRMS) analysis of its pentafluorobenzyl derivative. These IA columns were specific for epsilonGua and did not bind guanine, deoxyguanosine, 1, N(6)-ethenoadenine, or 1,N(2)-ethenoguanine. The level of recovery of standards from the IA columns was 107 +/- 7% and throughout the entire method (using nucleoside enzymatic digestion) with or without DNA was 72 +/- 6%. Four different hydrolysis/digestion procedures were compared, nucleoside enzymatic (EZ), neutral thermal hydrolysis (NT), formic acid hydrolysis (FA), and HCl hydrolysis. All hydrolysis methods with subsequent IA chromatography produced linear standard curves with r(2) values of 0.999 or better. The level of epsilonGua in chloroethylene oxide-treated calf thymus DNA (CEO-ctDNA) was 38 +/- 2, 42 +/- 3, and 49 +/- 2 fmol of epsilonGua/microg of DNA using EZ, NT, and FA, respectively. These numbers remained consistent when the amount of DNA processed was doubled or tripled. These numbers were comparable to the previously published value of 55 +/- 8 fmol of epsilonGua/micrograms of DNA for the same DNA using HCl hydrolysis, cation exchange cleanup, and LC/MS analysis [Yen, T. Y., et al. (1996) J. Mass Spectrom. 31, 1271-1276]. Additionally, HCl hydrolysis of rat liver DNA from control and vinyl fluoride-exposed rats gave similar epsilonGua results when compared to those from enzymatic digestion using this method. This method gave a detection limit of 5 epsilonGua adducts/10(8) normal dGuo nucleosides in 150 micrograms of DNA using EZ and somewhat lower detection limits using NT and HCl hydrolysis. The method is more sensitive and selective than previously used methods for the quantitation of this adduct.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DNA adducts with lipid peroxidation products
Blair, I. A. (2008) · Journal of Biological Chemistry · doi:10.1074/jbc.r700051200 · Cited by 253
Medeiros, M. H. G. (2009) · Chemical Research in Toxicology · doi:10.1021/tx800367d · Cited by 66
DNA Methylation Levels in Different Tissues in Tea Plant via an Optimized HPLC Method
Gao, Y., Hao, J.-L., Wang, Z., Song, K.-J., Ye, J.-H., Zheng, X.-Q., Liang, Y.-R., & Lu, J.-L. (2019) · Horticulture, Environment, and Biotechnology · doi:10.1007/s13580-019-00180-2 · Cited by 20
Metadata
- Authors
- Ham, A.-J. L., Ranasinghe, A., Morinello, E. J., Nakamura, J., Upton, P. B., Johnson, F., & Swenberg, J. A.
- Venue
- Chemical Research in Toxicology
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-11-19
- Volume
- 12
- Issue
- 12
- Pages
- 1240-1246
- ISSN
- 0893-228X (ISSN-L)
- 1520-5010
- OpenAlex
- W1990685264
- Cited by
- 38
- References
- 0
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.