The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
T-ray Imaging and Tomography
Open accessAbstract
We demonstrate two algorithms used forreconstructing the target's structure basedon the diffracted pulses and additionallyshow that a three-dimensional target can bereconstructed using the broadband pulsesand a Fresnel lens by virtue of itsfrequency dependent focal length. Oneadvantage of T-ray imaging is the abilityto measure the far-infrared spectralresponse of the target. To highlight theimportance of this spectral information, wedemonstrate T-ray classification imagingwith different biological samples using asimple classification algorithm and twodimensional T-ray spectroscopic images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Introduction to Fourier Optics
Sutton, P. (1996) · Quantum and Semiclassical Optics Journal of the European Optical Society Part B · doi:10.1088/1355-5111/8/5/014 · Cited by 5,023
Principles of Computerized Tomographic Imaging
Kak, A. C., Slaney, M., & Wang, G. (2002) · Medical Physics · doi:10.1118/1.1455742 · Cited by 1,909
Hu, B., & Nuss, M. C. (1995) · Optics Letters · doi:10.1364/ol.20.001716 · Cited by 1,643
Helgason, E., Økstad, O. A., Caugant, D. A., Johansen, H. A., Fouet, A., Mock, M., Hegna, I. K., & Kolstø, A. (2000) · Applied and Environmental Microbiology · doi:10.1128/aem.66.6.2627-2630.2000 · Cited by 1,072
Integrated THz technology for label-free genetic diagnostics
Nagel, M., Haring Bolivar, P., Brucherseifer, M., Kurz, H., Bosserhoff, A., & Büttner, R. (2002) · Applied Physics Letters · doi:10.1063/1.1428619 · Cited by 543
Mittleman, D. M., Hunsche, S., Boivin, L., & Nuss, M. C. (1997) · Optics Letters · doi:10.1364/ol.22.000904 · Cited by 519
Label-free probing of the binding state of DNA by time-domain terahertz sensing
Brucherseifer, M., Nagel, M., Bolívar, P. H., Kurz, H., Bosserhoff, A., & Büttner, R. (2000) · Applied Physics Letters · doi:10.1063/1.1332415 · Cited by 415
Gas sensing using terahertz time-domain spectroscopy
Mittleman, D. M., Jacobsen, R. H., Neelamani, R., Baraniuk, R. G., & Nuss, M. C. (1998) · Applied Physics B: Lasers and Optics · doi:10.1007/s003400050520 · Cited by 379 · cited 2×
“Mittleman’s group demonstrated real time gas mixture analysis using THz TDS [1].”
BackgroundMethodHunsche, S., Koch, M., Brener, I., et al. (1998) · Optics Communications · doi:10.1016/s0030-4018(98)00044-3 · Cited by 376
Pattern Classification: A Unified View of Statistical and Neural Approaches
Simonson, K. H., Schürmann, J., & Schurmann, J. (1997) · Technometrics · doi:10.2307/1270780 · Cited by 340
Ferguson, B. S., Wang, S., Gray, D., Abbott, D., & Zhang, X. (2002) · Optics Letters · doi:10.1364/ol.27.001312 · Cited by 319
Self-citationTerahertz time-domain spectroscopy
Nuss, M. C., & Orenstein, J. (2007) · Springer eBooks · doi:10.1007/bfb0103419 · Cited by 209
Pattern Classification: A Unified View of Statistical and Neural Approaches.
McLachlan, G. J., & Schürmann, J. (1998) · Biometrics · doi:10.2307/2534033 · Cited by 183
Single-shot spatiotemporal terahertz field imaging
Jiang, Z., & Zhang, X. (1998) · Optics Letters · doi:10.1364/ol.23.001114 · Cited by 165
Self-citationPattern Classification: A Unified View of Statistical and Neural Approaches
Simonson, K. H. (1997) · Technometrics · doi:10.1080/00401706.1997.10485447 · Cited by 147
Identification of biological tissue using chirped probe THz imaging
Ferguson, B. S., Wang, S., Gray, D., Abbott, D., & Zhang, X.-C. (2002) · Microelectronics Journal · doi:10.1016/s0026-2692(02)00109-x · Cited by 73
Self-citationAtomic and Molecular Spectroscopy
Svanberg, S. R. (1992) · Springer eBooks · doi:10.1007/978-3-642-97398-7 · Cited by 58
Characterization of T-ray binary lenses
Wang, S., Yuan, T., Walsby, E., et al. (2002) · Optics Letters · doi:10.1364/ol.27.001183 · Cited by 54
Self-citationTime reversal and object reconstruction with single-cycle pulses
Ruffin, A. B., Decker, J., Sanchez-Palencia, L., Hors, L. L., Whitaker, J. F., Norris, T. B., & Rudd, J. V. (2001) · Optics Letters · doi:10.1364/ol.26.000681 · Cited by 51
Towards functional 3D T-ray imaging
Ferguson, B. S., Wang, S., Gray, D., Abbott, D., & Zhang, X.-C. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/21/309 · Cited by 51
Self-citationTerahertz Time-Domain Spectroscopy
Nishizawa, S., Sakai, K., Hangyo, M., et al. (2005) · Topics in applied physics · doi:10.1007/10828028_7 · Cited by 51
Federici, J. F., Mitrofanov, O., Lee, M., Hsu, J. W. P., Brener, I., Harel, R., Wynn, J. D., Pfeiffer, L. N., & West, K. W. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/21/308 · Cited by 33
Cited by
Sorted by citations
Dynamic range in terahertz time-domain transmission and reflection spectroscopy
Jepsen, P. U., & Fischer, B. M. (2005) · Optics Letters · doi:10.1364/ol.30.000029 · Cited by 382
Withayachumnankul, W., Png, G. M., Yin, X., Atakaramians, S., Jones, I., Lin, H., Ung, B. S. Y., Balakrishnan, J., Ng, B. W.-H., Ferguson, B., et al. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.900325 · Cited by 179
Self-citation
Metadata
- Authors
- Wang, S., Ferguson, B., Abbott, D., & Zhang, X.-C.
- Affiliations
- Rensselaer Polytechnic Institute (US)
- The University of Adelaide (AU)
- Corresponding author
- Zhang, X.-C.
- Venue
- Journal of Biological Physics
- Published
- 2003-06
- Volume
- 29
- Issue
- 2-3
- Pages
- 247-256
- ISSN
- 0092-0606 (ISSN-L)
- 1573-0689
- PMC
- PMC3456432
- OpenAlex
- W2104116054
- Semantic Scholar
- 2db3b1bc25712449f6b4b7b5edcd74516a246d39
- Cited by
- 119
- References
- 24
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 2 · 2022: 5 · 2021: 8 · 2020: 4 · 2019: 2 · 2018: 4 · 2017: 3 · 2016: 10 · 2015: 5 · 2014: 6 · 2013: 7 · 2012: 7
- FWCI
- 5.69
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Biological Physics (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- Funders
- National Science Foundation (9986821)
- University of Canterbury
- US-UK Fulbright Commission
- Fulbright Australia
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microwave Imaging and Scattering Analysis
- Keywords
- terahertz imaging, terahertz tomography, image reconstruction, broadband pulses, Fresnel lens, biological specimen, terahertz spectroscopy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review