Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 231

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Constraints on thermochemical convection of the mantle from plume heat flux, plume excess temperature, and upper mantle temperature

Open access
Zhong, Shijie · 2006 · Journal of Geophysical Research: Solid Earth

Abstract

Seismic and geochemical observations indicate a compositionally heterogeneous mantle in the lower mantle, suggesting a layered mantle. The volume and composition of each layer, however, remain poorly constrained. This study seeks to constrain the layered mantle model from observed plume excess temperature, plume heat flux, and upper mantle temperature. Three‐dimensional spherical models of whole mantle and layered mantle convection are computed for different Rayleigh number, internal heat generation, buoyancy number, and bottom layer thickness for layered mantle models. The model results show that these observations are controlled by internal heating rate in the layer overlying the thermal boundary layer from which mantle plumes are originated. To reproduce the observations, internal heating rate needs ∼65% for whole mantle convection, but for layered mantle models, the internal heating rate for the top layer is ∼60–65% for averaged bottom layer thicknesses <∼1100 km. The heat flux at the core‐mantle boundary (CMB) is constrained to be ∼12.6 TW for whole mantle convection. For layered mantle, an upper bound on the CMB heat flux is ∼14.4 TW. For mantle secular cooling rate of ∼80 K/Ga, the current study suggests that the top layer of a layered mantle is relatively thick (>2520 km) and has radiogenic heat generation rate >2.82 × 10−12 W/kg that is >3 times of that for the depleted mantle source for mid‐ocean ridge basalts (DMM). For the top layer to have the radiogenic heat generation of the DMM, mantle secular cooling rate needs to exceed 145 K/Ga. The current study also shows that plume temperature in the upper mantle is about half of the CMB temperature for whole mantle convection or ∼0.6 of temperature at compositional boundary for a layered mantle, independent of internal heating rate and Rayleigh number. Finally, the model calculations confirm that mantle plumes accounts for the majority (∼80%) of CMB heat flux in whole mantle convection models. However, plume heat flux decreases significantly by as much as a factor of 3, as plumes ascend through the mantle to the upper mantle, owing to the adiabatic and possibly diffusive cooling of the plumes and owing to slight (∼180 K) subadiabaticity in mantle geotherm.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1029/2005jb003972

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 231

Metadata

Authors
Zhong, S.
Venue
Journal of Geophysical Research: Solid Earth
Published
2006-04
Volume
111
Issue
B4
ISSN
0148-0227 (ISSN-L)
OpenAlex
W2037340163
Cited by
231
References
4
FWCI
14.02
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Constraints on thermochemical convection of the mantle from plume heat flux, plume excess temperature, and upper mantle temperature. https://app.cochat.ai/papers/10.1029/2005jb003972
The paper
Zhong, S. (2006). Constraints on thermochemical convection of the mantle from plume heat flux, plume excess temperature, and upper mantle temperature. Journal of Geophysical Research: Solid Earth. https://doi.org/10.1029/2005jb003972

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.