Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 204

The DOI matches its Crossref record.

D/H and 18O/16O ratio in the hydronium ion and in neutral water from in situ ion measurements in comet Halley

Balsiger, H., Altwegg, K., Geiss, J.·1995·Journal of Geophysical Research: Space Physics

Abstract

The D/H ratio and the 18 O/16 O ratio in hydronium ions in the gas coma of comet Halley have been determined from ion data obtained by the high intensity sensor (HIS) of the ion mass spectrometer (IMS) on board the spacecraft Giotto in 1986. The HIS instrument measured reliable data for the water group ions over a large distance range from the nucleus. We could therefore minimize the statistical errors. This large range also allowed us to study the systematic influence of formaldehyde on the D/H ratio in the hydronium ion and to deduce from the hydronium ion a D/H ratio for the water molecule. The measured 18 O/16 O ratio of (1.93±0.12) × 10−3 is compatible with the telluric value of 2.06 × 10−3. The D/H ratio for the hydronium ion measured is D/H = 3.08−0.53+0.38 × 10−4. We show that since the water chemistry is not significantly different for deuterated and nondeuterated water molecules and ions and since the contribution from other deuterated molecules to the deuterium abundance in the hydronium ion is small, the D/H value of the neutral water molecule is not significantly different from the value determined for the ion, although the uncertainty is somewhat larger. An upper limit for the deuterium abundance in formaldehyde in comet Halley can be derived from the D/H ratio in the hydronium ion as a function of distance from the nucleus. From our results we conclude that the D/H ratio in formaldehyde is certainly smaller than 2% and probably smaller than 0.5% and that the enrichment of the deuterium in the hydronium ion due to formaldehyde is lower than 5%. The D/H ratio in water in comet Halley is therefore significantly higher than the telluric sea water value, whereas the deuterium enrichment in formaldehyde is not as high as, for example, that observed in the Orion compact ridge.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1029/94ja02936

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 204

Metadata

Authors
Balsiger, H., Altwegg, K., & Geiss, J.
Venue
Journal of Geophysical Research: Space Physics
Published
1995-04
Volume
100
Issue
A4
Pages
5827-5834
ISSN
0148-0227 (ISSN-L)
OpenAlex
W2042138594
Cited by
204
References
0
FWCI
8.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: D/H and 18O/16O ratio in the hydronium ion and in neutral water from in situ ion measurements in comet Halley. https://app.cochat.ai/papers/10.1029/94ja02936
The paper
Balsiger, H., Altwegg, K., & Geiss, J. (1995). D/H and 18O/16O ratio in the hydronium ion and in neutral water from in situ ion measurements in comet Halley. Journal of Geophysical Research: Space Physics. https://doi.org/10.1029/94ja02936

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.