Indoor air pollutants in schools: nasal patency and biomarkers in nasal lavage
Abstract
Background There is growing concern about the respiratory health aspects of the indoor air quality in schools. Methods A standardized investigation, including nasal lavage (NAL), measurement of the nasal cavity by acoustic rhinometry, and hygienic measurements of airborne pollutants, was performed in classrooms, outside the pollen season. All 279 school personnel working in the main buildings of 12 randomly selected primary schools in an urban community in central Sweden (Uppsala) were invited to enroll in the study; 234 (84%) participated. Eosinophil cationic protein (ECP), myeloperoxidase (MPO), lysozyme, and albumin were analyzed in NAL fluid. Crude statistical analysis, as well as multiple regression analysis, was performed, controlling for room temperature, age, sex, current smoking, and a history of atopy. Results Most classrooms (83%) did not meet the Swedish ventilation standards. A lower degree of nasal patency was found at higher concentrations of respirable dust, nitrogen dioxide (NO2), formaldehyde, and total molds, and in the presence of Aspergillus spp. in the classroom air. The most consistent findings were observed for formaldehyde, NO2, and Aspergillus spp., related to both decreased nasal patency and increase of ECP and lysozyme in NAL. The presence of yeast was associated with an increase of ECP and lysozyme in NAL, but was not related to nasal patency. Conclusions Ventilation flow was below current hygienic standards in the classrooms. Air pollutants in th…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Failure to prevent or respond promptly to indoor air quality problems can increase short- and long-term health outcomes.
“Failure to prevent or respond promptly to indoor air quality (IAQ) problems can increase short-and long-term health outcomes (Norbäck et al., 2000;Simoni et al., 2006;Tillet, 2010;Simoni et al., 2010), impact both teacher and student's attendance, comfort and performance (Gilliland et al., 2001;Shaughnessy et al., 2006;Mohai et al., 2011), and accelerate the deterioration of school buildings and”
From Comfort Parameters and Particulate Matter (PM10 and PM2.5) in School Classrooms and Outdoor Air (2013) · cites this paper as Norbäck et al., 2000
Cites
Horner, W. E., Helbling, A., Salvaggio, J. E., & Lehrer, S. B. (1995) · Clinical Microbiology Reviews · doi:10.1128/cmr.8.2.161 · Cited by 492 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034 · see citing works
Comfort Parameters and Particulate Matter (PM10 and PM2.5) in School Classrooms and Outdoor Air
Alves, C., Nunes, T., Silva, J., & Duarte, M. (2013) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2012.11.0321 · Cited by 88 · see citing works
“Failure to prevent or respond promptly to indoor air quality (IAQ) problems can increase short-and long-term health outcomes (Norbäck et al. , 2000; Simoni et al. , 2006; Tillet, 2010; Simoni et al. , 2010), impact both teacher and student’s attendance, comfort and performance (Gilliland et al. ,…”
- Authors
- Norbäck, D., Wålinder, R., Wieslander, G., Smedje, G., Erwall, C., & Venge, P.
- Affiliations
- Uppsala University (SE)
- Uppsala University Hospital (SE)
- Corresponding author
- Norbäck, D.
- Venue
- Allergy
- Publisher
- Wiley
- Published
- 2000-02
- Volume
- 55
- Issue
- 2
- Pages
- 163-170
- ISSN
- 0105-4538 (ISSN-L)
- 1398-9995
- OpenAlex
- W1987468233
- Cited by
- 102
- References
- 1
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 4 · 2022: 5 · 2021: 3 · 2020: 1 · 2019: 8 · 2018: 2 · 2017: 2 · 2016: 2 · 2015: 4 · 2014: 5 · 2013: 8 · 2012: 3
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Allergy (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Immunology and Allergy › Allergic Rhinitis and Sensitization
- Health Sciences › Medicine › Physiology › Asthma and respiratory diseases
- Keywords
- indoor air quality, school classrooms, nasal patency, eosinophil cationic protein, myeloperoxidase, lysozyme, Aspergillus, formaldehyde, nitrogen dioxide, respirable dust, mold exposure, ventilation standards, nasal mucosa inflammation, school staff
- MeSH terms
- Air Pollutants, Albumins, Blood Proteins, Cross-Sectional Studies, Humans, Middle Aged, Muramidase, Peroxidase, Nasal Cavity, Pulmonary Ventilation, Ribonucleases, Schools, Sweden, Air Pollution, Indoor, Nasal Lavage Fluid, Inflammation Mediators, Eosinophil Granule Proteins
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review