Abstract

This study was designed to validate a new home portable respiratory recording device (PRRD) to identify sleep apnoea and hypopnoea in a group of subjects (n=116), from a sample of the general population. Full night polysomnography (PSG) was used as the gold standard and simultaneously performed with PRRD. PRRD measurements included oronasal airflow (thermistry), chest wall impedance, oxygen saturation, snoring and body position. The sensors were unique for each recording system. Data obtained was blindly reviewed and analysed. A high level of agreement between both methods apnoea/hypopnoea index by PSG and the respiratory disturbance index (RDI) by PRRD was observed. Accuracy of the PRRD was evaluated in terms of sensitivity and specificity for different RDI-PRRD cut-off points with respect to AHI-PSG >10 and AHI-PSG >30. A logistic regression model was performed to estimate the chance per unit of RDI of apnoeas. A received operating characteristic (ROC) curve was drawn to obtain the sensitivity/specificity profile for each observed RDI value obtained. From the ROC curve the authors identified the better cut-off points, which represent a balanced sensitivity/specificity. Through a classification table defined by the cut-off point, the post-odds to exhibit the disease was calculated. For a full PSG cut-off point of 10 a PRRD of six showed a balanced sensitivity of 95% and a specificity of 92%. For a full PSG cut-off point of 30 a PRRD of 16 shows a balanced sensitivity/specificity (100% and 97%, respectively). Post odds of apnoea were calculated for each cut-off point. In conclusion, these data suggest that the portable respiratory recording device is an effective device to identify apnoeas and hypopnoeas in a general population and is therefore a suitable device to be used in epidemiological studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1399-3003.2000.16a22.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 58

Metadata

Authors
Ballester, E., Solans, M., Vila, X., Hernandez, L., Quintó, L., Bolivar, I., Bardagi, S., & Montserrat, J. M.
Venue
European Respiratory Journal
Published
2000-07
Volume
16
Issue
1
Pages
123
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2135546906
Cited by
58
References
3
FWCI
1.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of a portable respiratory recording device for detecting apnoeas and hypopnoeas in subjects from ageneral population. https://app.cochat.ai/papers/10.1034/j.1399-3003.2000.16a22.x
The paper
Ballester, E., Solans, M., Vila, X., Hernandez, L., Quintó, L., Bolivar, I., Bardagi, S., & Montserrat, J. M. (2000). Evaluation of a portable respiratory recording device for detecting apnoeas and hypopnoeas in subjects from ageneral population. European Respiratory Journal. https://doi.org/10.1034/j.1399-3003.2000.16a22.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.