Evaluation of a portable respiratory recording device for detecting apnoeas and hypopnoeas in subjects from ageneral population
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This study was designed to validate a new home portable respiratory recording device (PRRD) to identify sleep apnoea and hypopnoea in a group of subjects (n=116), from a sample of the general population. Full night polysomnography (PSG) was used as the gold standard and simultaneously performed with PRRD. PRRD measurements included oronasal airflow (thermistry), chest wall impedance, oxygen saturation, snoring and body position. The sensors were unique for each recording system. Data obtained was blindly reviewed and analysed. A high level of agreement between both methods apnoea/hypopnoea index by PSG and the respiratory disturbance index (RDI) by PRRD was observed. Accuracy of the PRRD was evaluated in terms of sensitivity and specificity for different RDI-PRRD cut-off points with respect to AHI-PSG >10 and AHI-PSG >30. A logistic regression model was performed to estimate the chance per unit of RDI of apnoeas. A received operating characteristic (ROC) curve was drawn to obtain the sensitivity/specificity profile for each observed RDI value obtained. From the ROC curve the authors identified the better cut-off points, which represent a balanced sensitivity/specificity. Through a classification table defined by the cut-off point, the post-odds to exhibit the disease was calculated. For a full PSG cut-off point of 10 a PRRD of six showed a balanced sensitivity of 95% and a specificity of 92%. For a full PSG cut-off point of 30 a PRRD of 16 shows a balanced sensitivity/specificity (100% and 97%, respectively). Post odds of apnoea were calculated for each cut-off point. In conclusion, these data suggest that the portable respiratory recording device is an effective device to identify apnoeas and hypopnoeas in a general population and is therefore a suitable device to be used in epidemiological studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Cited by
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Arias, M. A., García-Río, F., Alonso-Fernández, A., Mediano, O., Martínez, I., & Villamor, J. (2005) · Circulation · doi:10.1161/circulationaha.104.501841 · Cited by 420
Pulmonary hypertension in obstructive sleep apnoea: effects of continuous positive airway pressure
Arias, M. A., García-Río, F., Alonso-Fernández, A., Martínez, I., & Villamor, J. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi807 · Cited by 319
Effects of CPAP on oxidative stress and nitrate efficiency in sleep apnoea: a randomised trial
Alonso-Fernandez, A., Garcia-Rio, F., Arias, M. A., Hernanz, A., de la Pena, M., Pierola, J., Barcelo, A., Lopez-Collazo, E., & Agusti, A. (2009) · Thorax · doi:10.1136/thx.2008.100537 · Cited by 182
“, Barcelona, Spain)[24] that records oronasal airflow using a thermistor and nasal cannula prongs, chest wall impedance, oxygen saturation, snoring and body position was used to perform a sleep study in patients and healthy controls.”
Method
Metadata
- Authors
- Ballester, E., Solans, M., Vila, X., Hernandez, L., Quintó, L., Bolivar, I., Bardagi, S., & Montserrat, J. M.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2000-07
- Volume
- 16
- Issue
- 1
- Pages
- 123
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2135546906
- Cited by
- 58
- References
- 3
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of a portable respiratory recording device for detecting apnoeas and hypopnoeas in subjects from ageneral population. https://app.cochat.ai/papers/10.1034/j.1399-3003.2000.16a22.x
- The paper
- Ballester, E., Solans, M., Vila, X., Hernandez, L., Quintó, L., Bolivar, I., Bardagi, S., & Montserrat, J. M. (2000). Evaluation of a portable respiratory recording device for detecting apnoeas and hypopnoeas in subjects from ageneral population. European Respiratory Journal. https://doi.org/10.1034/j.1399-3003.2000.16a22.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.