CoChat

Pulmonary hypertension in obstructive sleep apnoea: effects of continuous positive airway pressure

Arias, Miguel A., García-Río, Francisco, Alonso-Fernández, Alberto, Martínez, Isabel, Villamor, José · 2006 · European Heart Journal

The DOI matches its Crossref record; 30 of the 31 references it cites were found in a registry or an index.

Abstract

Aims We tested the hypothesis that: (i) obstructive sleep apnoea (OSA) by itself originates pulmonary hypertension (PH); and (ii) the application of continuous positive airway pressure (CPAP) can reduce pulmonary pressure. Methods and results In this randomized and cross-over trial, 23 middle-aged OSA (apnoea-hypopnoea index, 44.1 +/- 29.3 h(-1)) and otherwise healthy patients and 10 control subjects were included. OSA patients randomly received either sham or effective CPAP for 12 weeks. Echocardiographic parameters, blood pressure recordings, and urinary catecholamine levels were obtained at baseline and after both treatment modalities. At baseline, OSA patients had higher pulmonary artery systolic pressure than control subjects (29.8 +/- 8.8 vs. 23.4 +/- 4.1 mmHg, respectively, P = 0.036). Ten out of 23 patients [43%, (95% CI: 23-64%)] and none of the control subjects had PH at baseline (P = 0.012). Two patients were removed from the study because of inadequate CPAP compliance. Effective CPAP induced a significant reduction in the values for pulmonary systolic pressure (from 28.9 +/- 8.6 to 24.0 +/- 5.8 mmHg, P Conclusion Severe OSA is independently associated with PH in direct relationship with disease severity and presence of diastolic dysfunction. Application of CPAP reduces pulmonary systolic pressure levels.

Overview

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehi807

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 30 references

Cited by

See all 321

Metadata

Authors
Arias, M. A., García-Río, F., Alonso-Fernández, A., Martínez, I., & Villamor, J.
Affiliations
Hospital Universitario La Paz (ES)
Venue
European Heart Journal
Published
2006-02-23
Volume
27
Issue
9
Pages
1106-1113
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2159083599
Cited by
319
References
31
Citations by year
2026: 4 · 2025: 10 · 2024: 17 · 2023: 3 · 2022: 13 · 2021: 16 · 2020: 13 · 2019: 9 · 2018: 7 · 2017: 15 · 2016: 19 · 2015: 29 · 2014: 21 · 2013: 23 · 2012: 16
FWCI
14.71
Type
journal article
Language
en
Open access
closed
Locations
  • European Heart Journal (publishedVersion)
  • PubMed (publishedVersion)
  • HighWire Press Open Archive (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Pulmonary Hypertension Research and Treatments
  • Health Sciences › Medicine › Pharmacology (medical) › Apelin-related biomedical research
Keywords
obstructive sleep apnea, pulmonary hypertension, continuous positive airway pressure, CPAP therapy, pulmonary artery systolic pressure, left ventricular diastolic dysfunction, urinary catecholamines, apnea-hypopnea index, disease severity
MeSH terms
Blood Pressure, Double-Blind Method, Echocardiography, Female, Forced Expiratory Volume, Humans, Hypertension, Pulmonary, Male, Middle Aged, Vital Capacity, Cross-Over Studies, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulmonary hypertension in obstructive sleep apnoea: effects of continuous positive airway pressure. https://app.cochat.ai/papers/10.1093/eurheartj/ehi807
The paper
Arias, M. A., García-Río, F., Alonso-Fernández, A., Martínez, I., & Villamor, J. (2006). Pulmonary hypertension in obstructive sleep apnoea: effects of continuous positive airway pressure. European Heart Journal. https://doi.org/10.1093/eurheartj/ehi807

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.