Guidelines for the use of EEG methodology in the diagnosis of epilepsy: International League Against Epilepsy: Commission Report Commission on European Affairs: Subcommission on European Guidelines
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The Commission of European Affairs of the International League Against Epilepsy published 'Appropriate Standards for Epilepsy Care Across Europe' which contained recommendations for the use of electroencephalography (EEG) in the diagnosis of epilepsy (Brodie et al. Epilepsia 1997; 38:1245). The need for a more specific basic document of EEG methodology was recognized and the Subcommission on European Affairs was asked to produce more detailed guidelines to be used across Europe recognizing the range of practices in EEG laboratories. There are many general guidelines published on EEG methodology but this document focuses on the diagnosis of epilepsy. Details from previously published guidelines are included in references and in an appendix. These guidelines are not meant to be used as minimal standards but recommendations that can be applied to all EEG laboratories despite variations in equipment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modern electroencephalography: its role in epilepsy management
Binnie, C. D., & Stefan, H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00125-x · Cited by 159 · cited 1×
“Using activation procedures, abnormalities are found in about 90% of patients with epilepsy (1).”
MethodGuideline Seven: A Proposal for Standard Montages to Be Used in Clinical EEG
(1994) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199401000-00008 · Cited by 25
Cited by
EEG in the diagnosis, classification, and management of patients with epilepsy
Smith, S. J. M. (2005) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2005.069245 · Cited by 798
Clinical utility of EEG in diagnosing and monitoring epilepsy in adults
Tatum, W. O., Rubboli, G., Kaplan, P. W., Mirsatari, S. M., Radhakrishnan, K., Gloss, D., Caboclo, L. O., Drislane, F. W., Koutroumanidis, M., Schomer, D. L., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.01.019 · Cited by 314
Differentiating between nonepileptic and epileptic seizures
Devinsky, O., Gazzola, D., & LaFrance, W. C. (2011) · Nature Reviews Neurology · doi:10.1038/nrneurol.2011.24 · Cited by 194
Increased Prevalence of Epilepsy Associated with Severe Falciparum Malaria in Children
Carter, J. A., Neville, B. G. R., White, S., Ross, A. J., Otieno, G., Mturi, N., Musumba, C., & Newton, C. R. J. C. (2004) · Epilepsia · doi:10.1111/j.0013-9580.2004.65103.x · Cited by 162
“(26) stated that a routine EEG recording in a child with epilepsy will have no epileptiform activity in ∼50% of cases.”
BackgroundSelf-citationHülsmeyer, V.-I., Fischer, A., Mandigers, P. J. J., DeRisio, L., Berendt, M., Rusbridge, C., Bhatti, S. F. M., Pakozdy, A., Patterson, E. E., Platt, S., et al. (2015) · BMC Veterinary Research · doi:10.1186/s12917-015-0463-0 · Cited by 123
Hyperventilation during electroencephalography: safety and efficacy
Kane, N., Grocott, L., Kandler, R., Lawrence, S., & Pang, C. (2014) · Seizure · doi:10.1016/j.seizure.2013.10.010 · Cited by 61
Metadata
- Authors
- Flink, R., Pedersen, B., Guekht, A. B., Malmgren, K., Michelucci, R., Neville, B., Pinto, F., Stephani, U., & Özkara, C.
- Venue
- Acta Neurologica Scandinavica
- Publisher
- Hindawi Limited
- Published
- 2002-06-14
- Volume
- 106
- Issue
- 1
- Pages
- 1-7
- ISSN
- 0001-6314 (ISSN-L)
- OpenAlex
- W4366067752
- Cited by
- 181
- References
- 2
- FWCI
- 1.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.