Manual vacuum aspiration, a safe and effective alternative in early pregnancy termination
The DOI matches its Crossref record.
Abstract
Background and objective. Vacuum aspiration has become standard surgical procedure for safe early pregnancy termination. Most of these operations are performed in the operating theater using suction curettage and an electric vacuum pump. MVA (manual vacuum aspiration) is an alternative that is well suited for use as a clinical procedure, which could have advantages both for the patient and the health care system. In order to compare conventional VA and MVA in a Swedish setting, a randomized study was undertaken. Methods. Two hundred women requesting abortion in early pregnancy, gestational age less than 56 days, and choosing surgical termination, were randomized to VA or MVA. Main study outcome was frequency of complete abortion but also other variables were recorded. Results. There were no significant differences between the two groups regarding background characteristics. Altogether 91 MVA and 88 VA operations were performed. There was no significant difference in frequency of complete abortion; two patients in each group subsequently needed re‐curettage because of incomplete evacuation. No case of ongoing pregnancy occurred. Two patients in each group received treatment for endometritis. No other complications were recorded. Conclusion. This study indicates that MVA is effective in emptying the uterine cavity, on par with the standard vacuum aspiration. The rate of complications with MVA was on the same low level as with conventional VA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Manual versus electric vacuum aspiration for first‐trimester abortion: a systematic review
Wen, J., Cai, Q., Deng, F., & Li, Y. (2008) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2007.01572.x · Cited by 96
(2011) · PubMed · Cited by 36
Beyond usual care: the economic consequences of expanding treatment options in early pregnancy loss
Dalton, V. K., Liang, A., Hutton, D. W., Zochowski, M. K., & Fendrick, A. M. (2015) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2014.08.031 · Cited by 22
Metadata
- Authors
- Hemlin, J., & Möller, B.
- Venue
- Acta Obstetricia et Gynecologica Scandinavica
- Publisher
- Wiley
- Published
- 2001-06
- Volume
- 80
- Issue
- 6
- Pages
- 563-567
- ISSN
- 0001-6349 (ISSN-L)
- 1600-0412
- OpenAlex
- W2140481803
- Cited by
- 63
- References
- 0
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Manual vacuum aspiration, a safe and effective alternative in early pregnancy termination. https://app.cochat.ai/papers/10.1034/j.1600-0412.2001.080006563.x
- The paper
- Hemlin, J., & Möller, B. (2001). Manual vacuum aspiration, a safe and effective alternative in early pregnancy termination. Acta Obstetricia et Gynecologica Scandinavica. https://doi.org/10.1034/j.1600-0412.2001.080006563.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.