Ultrasonographic endometrial thickness for diagnosing endometrial pathology in women with postmenopausal bleeding: a meta‐analysis

Gupta, Janesh K., Chien, Patrick F. W., Voit, Doris, Clark, T. Justin, Khan, Khalid S.·2002·Acta Obstetricia et Gynecologica Scandinavica

Abstract

Our aim was to determine the diagnostic accuracy of endometrial thickness measurement by pelvic ultrasonography for predicting endometrial carcinoma and disease (hyperplasia and/or carcinoma) during an investigation of postmenopausal bleeding. We performed a systematic quantitative review of the available published literature, which consisted of online searching the MEDLINE and EMBASE databases (1966–2000) coupled with scanning of bibliography of known primary and review articles. The selection of studies, assessment of study quality, and extraction of data were performed in duplicate under masked conditions. Included in the analyses were 57 studies with 9031 patients . Accuracy data were summarized using likelihood ratios for various cut‐off levels of abnormal endometrial thickness. The commonest cut‐offs were 4 mm (9 studies) and 5 mm (21 studies), measuring both endometrial layers. None of the nine studies using the ≤ 4 mm cut‐off level were of good quality. Only four studies (out of the 21) used the ≤ 5 mm cut‐off level, which employed the best‐quality criteria. Using the pooled estimates from these four studies only, a positive test result raised the probability of carcinoma from 14.0% (95% CI 13.3–14.7) to 31.3% (95% CI 26.1–36.3), while a negative test reduced it to 2.5% (95% CI 0.9–6.4). In conclusion, ultrasound measurement of endometrial thickness alone, using the best‐quality studies cannot be used to accurately rule. However, a negative result at ≤ 5 mm cut‐off level measuring both endometrial layers in the presence of endometrial pathology rules out endometrial pathology with good certainty.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-0412.2001.810902.x

Cites

72 of 72 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 72 references

Cited by

See all 282

Metadata

Authors
Gupta, J. K., Chien, P. F. W., Voit, D., Clark, T. J., & Khan, K. S.
Venue
Acta Obstetricia et Gynecologica Scandinavica
Publisher
Wiley
Published
2002-09
Volume
81
Issue
9
Pages
799-816
ISSN
  • 0001-6349 (ISSN-L)
  • 1600-0412
OpenAlex
W2139868277
Cited by
282
References
72
FWCI
10.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasonographic endometrial thickness for diagnosing endometrial pathology in women with postmenopausal bleeding: a meta‐analysis. https://app.cochat.ai/papers/10.1034/j.1600-0412.2001.810902.x
The paper
Gupta, J. K., Chien, P. F. W., Voit, D., Clark, T. J., & Khan, K. S. (2002). Ultrasonographic endometrial thickness for diagnosing endometrial pathology in women with postmenopausal bleeding: a meta‐analysis. Acta Obstetricia et Gynecologica Scandinavica. https://doi.org/10.1034/j.1600-0412.2001.810902.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.