Light microscopy of uveoscleral drainage routes after gelatine injections into the suprachoroidal space
Open accessThe DOI matches its Crossref record.
Abstract
PURPOSE: To visualize the suprachoroidal space and to study the morphology of possible uveoscleral drainage routes in the human eye. METHODS: Indian ink stained gelatine was injected directly into the suprachoroidal space of 7 human donor eyes. Those quadrants where gelatine appeared in the episcleral venous network were cut in their entirety in consecutive sections and examined by light microscopy. RESULTS: Gelatine was observed in the connective tissue surrounding scleral vessels and nerves. Gelatine was also traceable in fine, endothelium-lined channels at the inner aspect of the anterior sclera. These channels seemed to originate at the inner surface of the sclera, close behind the scleral spur, and communicate with the intrascleral venous plexus. CONCLUSION: Fluid is drained from the suprachoroidal space through the perivascular and perineural spaces of scleral blood vessels and nerves. In addition, this study indicates that there are preformed channels at the inner aspect of the anterior sclera, capable of draining fluid directly into scleral veins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Varela-Fernández, R., Díaz-Tomé, V., Luaces-Rodríguez, A., Conde-Penedo, A., García-Otero, X., Luzardo-Álvarez, A., Fernández-Ferreiro, A., & Otero-Espinar, F. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12030269 · Cited by 354
Suprachoroidal drug delivery to the back of the eye using hollow microneedles
Patel, S. R., Lin, A. S. P., Edelhauser, H. F., & Prausnitz, M. R. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0271-y · Cited by 330
“sclera and choroid that goes circumferentially around the eye (6,7).”
Cannulation of the suprachoroidal space: a novel drug delivery methodology to the posterior segment
Olsen, T. W., Feng, X., Wabner, K., Conston, S. R., Sierra, D. H., Folden, D. V., Smith, M. E., & Cameron, J. D. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.05.045 · Cited by 171
Drug delivery via the suprachoroidal space for the treatment of retinal diseases
Naftali Ben Haim, L., & Moisseiev, E. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13070967 · Cited by 68
“The choroid and sclera are usually in close contact with each other due to the IOP [8] and attaching fibers [9], making the SCS a potential space which is created with the accumulation of fluid which may be introduced either internally or externally.”
Background
Metadata
- Authors
- Krohn, J., & Bertelsen, T.
- Venue
- Acta Ophthalmologica Scandinavica
- Publisher
- Wiley
- Published
- 1998-10
- Volume
- 76
- Issue
- 5
- Pages
- 521-527
- ISSN
- 1395-3907 (ISSN-L)
- 1600-0420
- OpenAlex
- W2094025215
- Cited by
- 43
- References
- 0
- FWCI
- 0.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Light microscopy of uveoscleral drainage routes after gelatine injections into the suprachoroidal space. https://app.cochat.ai/papers/10.1034/j.1600-0420.1998.760502.x
- The paper
- Krohn, J., & Bertelsen, T. (1998). Light microscopy of uveoscleral drainage routes after gelatine injections into the suprachoroidal space. Acta Ophthalmologica Scandinavica. https://doi.org/10.1034/j.1600-0420.1998.760502.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.